PARTS INFORMATION
If you require replacement parts or would like to purchase
accessories, inside the U.S., please call Ohaus Corporation
toll-free at (800) 526-0659 and from outside the U.S., (973)
377-9000. An Ohaus Product Parts Specialist will be available
to help you.

REPLACEMENT PARTS

Part No.

AC Adapters:

US/Japan 100 V

11103743

US 100-120V

11103741

Europe 220-240V

11103740

UK 220-240V

11103742

Table version 220-240V Reqs. sep. line cord, Aus. 11103745

Line cord for above

76199-01

Table version 220-240V Reqs. sep. line cord, US 11103745

Line cord for above

6569-00

Euro/Germany, Belgium, France 220-240V

11103744

Pan for 65g, 110g, 210g 3.5" (9cm) dia.

12106739

Pan for 150g, 310g,

3.9" (10cm) dia.

12105372

Pan for 510 to 4100g,

7.1" (18cm)

12105370

ACCESSORIES

Part No.

20g Calibration Mass

49024-11

50g Calibration Mass

49054-11

100g Calibration Mass

49015-11

200g Calibration Mass

49025-11

500g Calibration Mass

49055-11

1kg Calibration Mass

49016-11

2kg Calibration Mass

49026-11

Security Device

76288-01

Impact printer

SF42

In-Use Cover

400302-010

Error Codes

When a problem occurs using the balance, the display will indi-
cate an error code. Review the listed codes and follow instruc-
tions to correct the problem.

Err 2.0 Stability error. Check if balance is located near vibrat-

ing equipment or if air currents are affecting it.

Err 3.0 Calibration error (wrong mass). Incorrect or no cali-

bration mass used when performing calibration proce-
dure. Error will flash momentarily, then balance will
use previous calibration data. Recalibrate correctly.

Err 4

Invalid data checksum in type or adjust data. Return
balance for servicing.

Err 6.0 Parts counting error - Average piece weight is less than

1d. Balance shows error then exits parts counting.

Err 8.4 Over or under load. Sample being weighed exceeds

the capacity of the balance. If error occurs when the
sample is within the balance capacity, balance may be
incorrectly calibrated. An underload such as the pan
off of the balance could also display Err 8.4. Recali-
brate the balance.

Err 9

Internal data error. Return balance for servicing.

Err 9.8 Invalid checksum in calibration or setup data. The

balance may need recalibration, particularly linearity
calibration. If the error persists after recalibration,
the balance must be serviced.

Capacity

65g

(1)

110g

(1)

210g

(1)

150g

(1)

210g

(1)

310g

(1)

410g

(1)

510g

1500g 2100g

3100g 4100g

Readability

0.1mg 0.001g

0.01g

0.1g

Weighing units/modes

g, kg, mg, ct, N, lb, oz, ozt, gn, dwt, momme, mesghal, 3 taels, ticals, Parts Counting

Repeatability (Std. Dev.)

0.1mg

0.001g

0.01g

0.1g

Linearity

±0.2mg

±0.3mg

±0.002g

±0.01g ±0.02g

±0.1g

Tare Range

Full capacity by subtraction

Stabilization Time (seconds)

3 Seconds

Sensitivity Drift

4ppm/°C

10ppm/°C

Operating Temp Range

50° to 86° F/10° to 30° C

Power Requirements

8 - 14.5V 50/60Hz 6VA or 9.5 - 20V 6W

Calibration

External Digital

Display (in/cm)

LCD (1.2/3 high)

Pan Size (in/cm)

3.5/9 dia.

3.9/10 dia.

7.1/18 dia.

Draft shield clearance height

9.3/23.6

6.8/17.25

above pan (in/cm)

Dimensions (WxHxD) (in/cm)

8.5x14.3x13.5/21.7x36.3x34.3 8.5x12.3x13.5/21.7x31x34.3

8.5x4.3x13.5/21.7x11x34.3

Net Wt (lb/kg)

12.5/5.7

10/4.5

8.5/3.9

Shipping Wt (lb/kg)

21/9.5

16/7.3

14/6.4

Item No.

AR0640 AR1140 AR2140 AR1530 AR2130 AR3130 AR4130 AR5120 ARA520 ARB120 ARC120 ARD110

SPECIFICATIONS

Notes 1. 65g to 310g analytical balances include a three door draft shield.

2. Some models are not available in all countries.