Intuitive applications, Vascular – GE Healthcare Optima MR450w 1.5T User Manual
Page 15

Inhance Inflow IR
256 x 256 2 mm
VASCULAR
Inhance Delaflow
3 stations w/ ARC
INTUITIVE APPLICATIONS.
CONTRAST WITHOUT CONTRAST
3D ASL
Non-contrast brain perfusion. Quantitative
perfusion imaging without contrast.
Inhance Inflow IR
Consistent and reliable non-contrast, free-
breathing imaging of the arterial and venous
vascular, such as the renal and portal vein.
Inhance DeltaFlow
High-resolution, rapid, non-contrast lower
extremity/peripheral vascular three-station
imaging typically in less than six minutes.
Inhance 3D Velocity
High-resolution, fast, non-contrast imaging of the
arterial and venous structure in the brain.
BREAST
VIBRANT Flex
Generates up to four contrasts with high-resolution
in just one short scan and virtually eliminates fat
suppression failures in breast imaging, even over a
large FOV with irregular anatomy.
VIBRANT
Lays the foundation of breast MRI with a high
combined spatial detail and scanning speed
including bilateral shimming to ensure uniform
bilateral fat saturation.
Breast Biopsy
In-room Operator Console (iROC) supports needle
localization for breast biopsy.
NEURO
Cube
3D FSE-based sequence for isotropic resolution in
all contrasts (T1, T2, & T2 FLAIR).
SWAN
High-resolution visualization and delineation of
small vessels and microbleeds.
PROPELLER
Motion-insensitive T1 FLAIR, T2, T2 FLAIR and DWI
for efficient imaging of uncooperative patients.
3D MERGE
Improves grey-white matter contrast in the
spinal cord.
MUSCULOSKELETAL
PROPELLER
Motion-insensitive T1, T2 and PD imaging to
improve the visualization of subtle structures such
as cartilage, meniscus, ligaments and labrum.
IDEAL
This unique fat/water separation technique
provides multiple contrasts from one acquisition
for consistent, uniform fat suppression virtually
every time.
CartiGram
A non-invasive imaging method to assess
articular cartilage integrity, detect early cartilage
degeneration and monitor patient progress.
BODY
LAVA Flex
A rapid 3D sequence for consistent and reliable
fat saturation in one breath hold.
MRCP (MR cholangiography)
High-resolution reliable visualization of the biliary
ducts.
PROPELLER
Motion-insensitive, free-breathing T2 abdominal
imaging.
Whole Body w/ GEM Suite
Perform whole body imaging without
repositioning the patient or coils.
MR-Touch
Non-invasive measure of liver stiffness.
eDWI
Ability to visualize pathology and measure ADC
values in a single breath hold in the liver and
beyond.
Inhance 3D Velocity
320 x 256 1.2 mm