Intuitive applications, See to understand. needle-free suite – GE Healthcare Optima MR360 1.5T Advance User Manual
Page 13
LAVA Flex
LAVA Flex is a 3D FSPGR imaging
technique that acquires fat/water
in-phase and out-of-phase echoes in
a single acquisition. Up to four types
of image contrasts may be achieved
within one acquisition: in-phase, out-
of-phase, water-only and fat-only.
3D ASL (Arterial spin labeling)
3D ASL utilizes water in arterial blood
as an endogenous contrast medium
to help visualize tissue perfusion and
provide quantitative assessment of
cerebral blood flow.
Inhance non-contrast MRA Suite
The Inhance non-contrast MRA Suite
is a series of non-contrast enhanced
techniques designed to image
vasculature of the brain, abdomen
and legs with excellent background
suppression in short exam times.
3D Heart
The whole heart volume is acquired
in several slabs, using a multi-slab
localizer that allows easy whole-
heart imaging for coronary arteries.
NEURO
Brain
T1 FLAIR PROPELLER Axial
288 x 288
Shoulder
PD PROPELLER Fat Sat Coronal
256 x 256 4 mm
Brain
SWAN
384 x 320 1.8 mm
Knee
PD PROPELLER Fat Sat Coronal
288 x 288 4 mm
Brain
T1 Cube Sagittal
288 x 288 1.2 mm
Abdomen
LAVA Flex Axial
320 x 224 4.22 mm
Brain
3D ASL Axial
Fusion to BRAVO
Abdomen
T2 PROPELLER Fat Sat Axial
320 x 320 6mm
T-Spine
T2 frFSE Sagittal
416 x 288 3 mm
Cardiac
FIESTA 4-chamber
224 x 256
C-Spine
T2 PROPELLER Sagittal
320 x 320 3 mm
C-Spine
T1 FLAIR PROPELLER Sagittal
288 x 288
Cardiac
3D Heart
224 x 256 2 mm
Brachial Plexus
T2 IDEAL Coronal
256 x 224 3 mm
Inhance Deltaflow
3 stations
MUSCULOSKELETAL
BODY
VASCULAR
PROPELLER 3.0
PROPELLER has low sensitivity to motion
artifacts and high contrast-to-noise
properties. This makes it well suited for
producing high-resolution image quality
even under challenging circumstances.
MR Touch
MR Touch is a non-invasive method to
measure relative tissue stiffness with MR. MR
Touch combines hardware, acquisition and
reconstruction algorithms to produce color-coded
anatomical images, called elastograms, showing
varying degrees of elasticity or stiffness.
IDEAL IQ
IDEAL IQ is an exclusive technique that builds upon
the original IDEAL (iterative decomposition of water
and fat with echo asymmetry and least-squares
estimation) technique. IDEAL IQ acquires multiple
images of the anatomy at separate echo times
to calculate the phase differences and determine
triglyceride fat and water content per pixel.
INTUITIVE
APPLICATIONS.
SEE TO UNDERSTAND.
NEEDLE-FREE SUITE.
Even with the right balance of design and technology, intuitive
applications are what truly drive better understanding of what
you need to see. The Optima MR360 Advance offers innovative
applications to help you utilize the full potential of 1.5T MR imaging.
How can you reduce the use of needles in certain exams? Our answer
is the Needle-Free Suite of MR applications. Take advantage of what
Needle-Free can offer with potential cost-savings for you and your facility,
faster workflow for your technologists and a more comfortable imaging
experience for your patients. For example, by avoiding contrast, you could
do up to three additional procedures per day that could translate into over
$77,000 in additional revenue
1
.
LESS BIOPSIES
LESS CONTRAST
LESS SEDATION