beautypg.com

GE Healthcare CT Perfusion 4D Neuro User Manual

Page 2

background image

Features

Visualize all information in true
volumetric form with the ability to
employ all the volumetric-based
image analysis tools in the AW
Volume Viewer.

Smart Maps using the intelligent 4D
noise suppression algorithm
improves functional map image
quality in the presence of noise.

Streamlined tissue classification
and visualization incorporates
thresholding of Blood Volume with
any one of Tmax, MTT or Blood
Flow.

Productivity enhancements
include:
- Automated vessel detection
- Progressive functional maps

computation.

- Volumetric visualization of

functional maps

- Access from anywhere using AW

Server.

Many basic features, including the
ability to:
- Process double phase acquisition

data.

- Create 4D ROIs.
- Display ROI statistical

information.

- Display averaged time intensity

information of an ROI.

- Simultaneously review any

number of functional maps.

- Customize protocols
- Save parameters.

Fully integrated CT brain stroke
protocol that performs the
following algorithmic steps:
‐ Image registration
‐ Bone removal

Indications for Use

CT perfusion 4D is an image analysis
software package that allows the
user to produce dynamic image data
and to generate information with
regard to changes in image intensity
over time. It supports the analysis of
CT Perfusion images, obtained by
cine imaging (in the head and body)
after the intravenous injection of
contrast, in calculation of the various
perfusion-related parameters (i.e.
regional blood flow, regional blood
volume, mean transit time and
capillary permeability).
The results are displayed in a user-
friendly graphic format as parametric
images. This software will aid in the
assessment of the extent and

type of

perfusion, blood volume and capillary
permeability changes, which may be
related to stroke or tumor
angiogenesis and the treatment

thereof.

Regulatory Compliance

This product complies with the
European Council Directive
93/42/EEC Medical Device Directive
as amended by European Council
Directive 2007/47/EC

‐ Arterial input
‐ Venous output
‐ Last pre-enhancement/first post-

enhancement image

‐ Final settings and compute

Fully integrated CT brain tumor
protocol.

Functional maps:
‐ Regional cerebral blood volume
‐ Regional cerebral blood flow
‐ Regional mean transit time
‐ Contrast arrival delay
‐ Transit time to peak of impulse

residue function

‐ Capillary permeability surface

area

‐ Base image
‐ Average image

Operation Summary

1. Select and load image data set.
2. Automatic detection of the Artery

and Vein ROI’s.

3. Display and plot time-intensity

information.

4. Create parametric image.
5. Overlay functional map onto

reference image.

6. Display functional data.
7. Save and print processed data.

System Requirements

AW Workstation Volume Share 5 or
higher.

AW Server.

Recommendations:

12GB RAM

2 display monitors (also compatible
with single monitor).

© 2012 General Electric Company.

All rights reserved. Data subject to change.

GE and GE Monogram are trademarks of General Electric Company.

* Trademark of General Electric Company.