Persistent mode, Maintenance, Introduction – American Magnetics AMI Superconducting Magnets User Manual
Page 3
2
Introduction
Persistent Mode
After it has been energized, a superconducting magnet can be operated in the
persistent mode by short circuiting the magnet with a superconductor. This is
accomplished by connecting a section of superconducting wire contained in the
persistent switch across the terminals of the magnet. This section of superconductor
can be heated to drive it into the resistive state so a voltage can be established across
the terminals and the magnet can be charged or discharged. After reaching the desired
field, the heater is turned off and the magnet is shorted by the switch.
Maintenance
AMI magnets are designed and constructed so as to provide years of useful service
and require no maintenance if installed and operated in accordance with these
instructions.
- 12200PS DC Power Supply (CE-Marked) (58 pages)
- MAxes Multi-Axis Magnet systems for Vector Fields (4 pages)
- 05200PS-430-601 High Stability Integrated Power Supply System (226 pages)
- Current Leads for Cryogenic Systems Brochure (8 pages)
- 150A Portable Liquid Helium Level Meter (CE-Marked) (7 pages)
- AMI Liquid Helium Level Sensors (7 pages)
- 12100PS DC Power Supply (CE-Marked) (53 pages)
- 187 Self-Compensating Liquid Level Controller (75 pages)
- 286 Multi-Sensor Liquid Level Instrument (CE-Marked) (116 pages)
- 601 Energy Absorber (CE-Marked) (7 pages)
- 05100PS-430-601 Integrated Power Supply System (224 pages)
- 4Q06125PS-430 Integrated Power Supply System (216 pages)
- SVTI-CH6022-2 (2 pages)
- OPMX-141-1 (2 pages)
- 05500PS-430-601 High Stability Integrated Power Supply System (228 pages)
- 188CPS Point-Sensing Instrument (29 pages)
- MX-4.5_9-30 (2 pages)
- 4Q05100PS Four-Quadrant Power Supply (7 pages)
- Current Leads for Cryogenic Systems Manual (10 pages)
- SD-6-15 (2 pages)
- CRYOGEN FREE SUPERCONDUCTING MAGNET SYSTEMS (4 pages)
- 4Q06250PS-430 Integrated Power Supply System (216 pages)
- 4Q12125PS-430 Integrated Power Supply System (216 pages)
- 430 Power Supply Programmer (4 pages)
- 110 Liquid Helium Level Meter (CE-Marked) (30 pages)
- 420 Power Supply Programmer (134 pages)
- 175 Industrial Level Transmitter (CE-Marked) (18 pages)
- 05100PS-430-601 High Stability Integrated Power Supply System (226 pages)
- 4Q12125PS-430 High Stability Integrated Power Supply System (216 pages)
- 4Q06125PS-430 High Stability Integrated Power Supply System (216 pages)
- 4Q1005PS-430 Integrated Power Supply System (214 pages)
- 160 Liquid Helium Level Superconducting Dipstick (4 pages)
- 05200PS-430-601 Integrated Power Supply System (224 pages)
- 4Q1010PS-430 Integrated Power Supply System (214 pages)
- 05300PS-430-601 High Stability Integrated Power Supply System (226 pages)
- 4Q06250PS-430 High Stability Integrated Power Supply System (216 pages)
- 185 & 186 Liquid Level Instruments (CE-Marked) (82 pages)
- 03300PS-430-601 High Stability Integrated Power Supply System (226 pages)
- 135 & 136 Liquid Helium Level Instruments (CE-Marked) (72 pages)