Dell DX6004S User Manual
Page 11

Getting Started With Your System
9
Heat dissipation
1571 BTU/hr maximum (non-redundant
power supply)
1666 BTU/hr maximum (redundant
power supply)
Maximum inrush current
Under typical line conditions and over the entire
system ambient operating range, the inrush
current may reach 25 A per power supply for
10 ms or less
Batteries
System battery
CR 2032 3.0-V lithium coin cell
Physical
Height
4.29 cm (1.69 in)
Width
43.4 cm (17.09 in)
Depth
61.26 cm (24.12 in)
Weight (maximum configuration) 15 kg (33.02 lbs)
Weight (empty configuration)
5.96 kg (13.12 lbs)
Environmental
NOTE:
For additional information about environmental measurements for specific
system configurations, see
www.dell.com/environmental_datasheets.
Temperature
Operating
10° to 35°C (50° to 95°F) with a maximum
temperature gradation of 10°C per hour
NOTE:
For altitudes above 2950 feet, the maximum
operating temperature is derated 1ºF/550 ft.
Storage
–40° to 65°C (–40° to 149°F) with a maximum
temperature gradation of 20°C per hour
Relative humidity
Operating
8% to 85% (noncondensing) with a maximum
humidity gradation of 10% per hour
Storage
5% to 95% (noncondensing)
Power (continued)