Summary of minimum requirements, Operating frequencies, Output power – ACR&Artex SLB406 ELT User Manual
Page 35: Activation, Temperature, Fire resistance, Input power, Mechanical characteristics

ARTEX PRODUCTS / ACR ELECTRONICS, INC
DESCRIPTION, OPERATION, INSTALLATION AND MAINTENANCE MANUAL
SLB 406 ELT
Page 35 of 43
MAR 27/11
570-6700 Rev. B
Initial Issue DEC 19/2006
Weight
737 g (including battery pack)
Volume
557 cm
3
Design Specifications
RTCA DO-204
RTCA DO-183
COSPAS-SARSAT T.001
Summary of Minimum Requirements
Operating Frequencies
406.028 MHz +/- 2 kHz Bi-phase L; Emission designator G1D
121.5 MHz +/-6.0 kHz AM; Emission designator A3X
Output Power
406 MHz: 37 dBm ± 2 dBm (3.16W Min to 7.94 W Max) (440 ms / 50 sec) PERP or
EIRP for 24 hours @ -20ºC to +55ºC
121.5 MHz: >/= 20.0 dBm (100mW) PERP for 50 hours or EIRP for 48 hours @ -20ºC
to +55ºC
Activation
Manual or Auto Activation Lanyard
Temperature
Storage: -55ºC to +85ºC
Operational: -20ºC to +55ºC
Fire Resistance
15 sec. flame per RTCA/DO-204 §2.3.7.1
Input Power
None
Mechanical Characteristics
Vibration: 10 G’s, 5Hz to 2000Hz
Shock: 50 G’s for 11 ms