beautypg.com

Maintenance, Periodic maintenance – ACR&Artex SLB406 ELT User Manual

Page 25

background image

ARTEX PRODUCTS / ACR ELECTRONICS, INC

DESCRIPTION, OPERATION, INSTALLATION AND MAINTENANCE MANUAL

SLB 406 ELT

Page 25 of 43

MAR 27/11

570-6700 Rev. B

Initial Issue DEC 19/2006

Maintenance

This section describes minimum continued airworthiness requirements that can be

performed by the aircraft owner/operator. Additional maintenance must be performed

by an authorized Artex Repair Station.

Periodic maintenance

In the United States, minimum maintenance requirements for ELTs are stated in FAR

91.207 paragraph (d):

(d) Each emergency locator transmitter required by paragraph (a) of this

section must be inspected within 12 calendar months after the last inspection

for--

(1) Proper installation;

(2) Battery corrosion;

(3) Operation of the controls and crash sensor; and

(4) The presence of a sufficient signal radiated from its antenna.

To ensure continued reliability and airworthiness, your ELT must be inspected for

damage and wear caused by age, exposed elements, vibration, etc. Inspections are also

to take place annually per FAR Part 91.409. FAR 43, Appendix D(i) states in part that

each person performing an annual or 100-hour inspection shall inspect the following

components of (the ELT):

(1) (ELT unit and mount) for improper installation and insecure mounting.

(2) Wiring and conduits - for improper routing, insecure mounting, and obvious defects.

(3) Bonding and shielding - for improper installation and poor condition.

(4) Antenna, including trailing antenna-for poor condition, insecure mounting, and

improper operation.

NOTE: All references to maintenance requirements for the United States shall also apply

to all ELT users outside of the US unless otherwise required by the installer / aircraft

maintenance procedures or the relevant national regulations.

NOTE:

All references to test equipment are generic; Artex makes no specific

equipment references (by manufacturer, etc). All tests described herein must be

performed by qualified personnel that are familiar with test equipment as well as

the specifications and parameters described.