beautypg.com

Functions, Activation – ACR&Artex SLB406 ELT User Manual

Page 17

background image

ARTEX PRODUCTS / ACR ELECTRONICS, INC

DESCRIPTION, OPERATION, INSTALLATION AND MAINTENANCE MANUAL

SLB 406 ELT

Page 17 of 43

MAR 27/11

570-6700 Rev. B

Initial Issue DEC 19/2006

THIS TRANSMITTER IS AUTHORIZED FOR USE ONLY DURING SITUATIONS OF GRAVE

AND IMMINENT DANGER, WHEN ALL OTHER MEANS OF SELF RESCUE HAVE BEEN

EXHAUSTED.
OFF:

Press for approximately 2 seconds to turn SLB off.

TEST:

Press for approximately 2 seconds to initiate Self Test operations.

XMIT:

LED flashes Red once every two seconds indicating Normal Operation.

During an actual 406 MHz transmission (nominally every 50 seconds), the LED stays Red

for the full 406 MHz pulse transmission –approximately one second.
PASS:

LED flashes green for 60 seconds indicating a successful Self Test

operation.
FAIL:

LED flashes red for 60 seconds indicating a failed Self Test operation.

Functions

Activation

The SLB 406 can be activated in two modes: 1) Automatic Activation, and 2) Manual

Activation. The Automatic Activation mode requires the use of the automatic activation

lanyard/Activation Lanyard attached to a life raft or the inflatable portion of a life vest.

In this mode the beacon will be automatically activated upon life vest/raft inflation

without any user action. Beacon activation occurs when the activation lanyard is

separated from the beacon. When the beacon is activated, the red XMIT LED will

illuminate for approximately one second to acknowledge. To activate the SLB 406 in the

Manual Activation mode, press the ACTIVATE button for approximately two seconds

until the red XMIT light illuminates. When the beacon is activated, the red XMIT LED will

illuminate for approximately one second to acknowledge. Figure 5 shows the protective

faceplate of the SLB 406 which protects the buttons from inadvertent activation or

turnoff.

Figure 5 – Protective Face Plate