Functions, Activation – ACR&Artex SLB406 ELT User Manual
Page 17
ARTEX PRODUCTS / ACR ELECTRONICS, INC
DESCRIPTION, OPERATION, INSTALLATION AND MAINTENANCE MANUAL
SLB 406 ELT
Page 17 of 43
MAR 27/11
570-6700 Rev. B
Initial Issue DEC 19/2006
THIS TRANSMITTER IS AUTHORIZED FOR USE ONLY DURING SITUATIONS OF GRAVE
AND IMMINENT DANGER, WHEN ALL OTHER MEANS OF SELF RESCUE HAVE BEEN
EXHAUSTED.
OFF:
Press for approximately 2 seconds to turn SLB off.
TEST:
Press for approximately 2 seconds to initiate Self Test operations.
XMIT:
LED flashes Red once every two seconds indicating Normal Operation.
During an actual 406 MHz transmission (nominally every 50 seconds), the LED stays Red
for the full 406 MHz pulse transmission –approximately one second.
PASS:
LED flashes green for 60 seconds indicating a successful Self Test
operation.
FAIL:
LED flashes red for 60 seconds indicating a failed Self Test operation.
Functions
Activation
The SLB 406 can be activated in two modes: 1) Automatic Activation, and 2) Manual
Activation. The Automatic Activation mode requires the use of the automatic activation
lanyard/Activation Lanyard attached to a life raft or the inflatable portion of a life vest.
In this mode the beacon will be automatically activated upon life vest/raft inflation
without any user action. Beacon activation occurs when the activation lanyard is
separated from the beacon. When the beacon is activated, the red XMIT LED will
illuminate for approximately one second to acknowledge. To activate the SLB 406 in the
Manual Activation mode, press the ACTIVATE button for approximately two seconds
until the red XMIT light illuminates. When the beacon is activated, the red XMIT LED will
illuminate for approximately one second to acknowledge. Figure 5 shows the protective
faceplate of the SLB 406 which protects the buttons from inadvertent activation or
turnoff.
Figure 5 – Protective Face Plate