Accusys ExaSAN A12S2-PS User Manual
Page 14
Follow these steps to install the card in each host system:
1. Make sure that the client system is turned off.
2. Open the client system’s outer casing cover, check with
your vendor documentation for instructions if necessary.
3. Re-position the HBA card so that you are facing jumper
switch as shown below. You can use the jumper switch to
configure the HBA for DAS or SAN usage. Set the jumper
switch before installing into the host.
* DAS mode: When the switch is in the "On” position, the
HBA card is enabled for RAID (Direct-Attached Storage
A12S2-PS) mode.
* SAN mode: In the “1” position, the HBA is enabled for
switch (SAN) mode.
4. Locate the available PCIe slot. Remove the blank plate if
one is present and save the screw for later use.
5. Position the connector of the card over the slot and then
insert the connector into the slot. Press gently but firmly
until it is securely seated.
P10