beautypg.com

Acclaim Lighting ART IO User Manual

Page 34

background image

The Show Control page is prepared with templates of operations that are very typical usage of the Art
IO. The following tables describes those templates.

Art-Net → DMX

Converts incoming Art-Net to DMX. The DMX port needs to be set to output.

DMX → Art-Net

Converts incoming DMX to Art-Net. The DMX port needs to be set to input.

DMX → Outputs

Control the relays by DMX channel 1 through 8. Values below 50% switch the relay off,
values above 50% will swich it on. The DMX port needs to be set to input.

Art-Net → Outputs

Control the GPOs by incoming Art-Net channel 1 through 8. Values below 50% switch the
relay off, values above 50% will swich it on. The DMX port needs to be set to input.

Inputs → DMX

Convert the state of the GPI to DMX channels 1 through 8. When a GPI is to digital the DMX
channel will switch between value 0 and 255, when set to analogue the channel will range
between 0 and 255. The DMX port needs to be set to output.

Inputs → Art-Net

Convert the state of the GPI to Art-Net channels 1 through 8. When a GPI is to digital the
Art-Net channel will switch between value 0 and 255, when set to analogue the channel
will range between 0 and 255.

Inputs → OSC

Convert the state of the GPI to OSC. The OSC URI is /gpiX, where X is the GPI port number.

OSC → Outputs

Control the GPOs by incoming OSC messages. The OSC URI is /gpoX, where X is the GPO
port number.

Demo

This demonstrates the capability of the Art IO by connecting the GPI's and GPO's to
various protocols like DMX, OSC and aTouch.

Production Test

This template is used for testing the device during the production process.