CHANGING THE GAS TYPE :
the calorific power output and gas pressure will
vary according to the gas supply. Burner setting must be carried out once the gas and
electrical installation is complete.
When changing gas type, you must follow the procedure below :
. fit the correct jets,
. adjust the appearance of the flame by regulating the air ring.
. adjust the minimum flame on the taps (see page 30).
CHANGING THE JETS
:
Each jet is designated by size. A special spanner supplied with the appliance is designed to
hold the jets securely during the set up operation.
To gain access to the jets :
. remove the pan supports,
. remove the burner cap and body,
. using the spanner supplied with the appliance, unscrew
the jet,
. fit the correct jet for the type of gas to be used,
. secure the jet tightly,
. replace the burner body, cap and the pan support.
INSTALLATION: "GAS CONNECTION"
Jet
Burner
body
Example : Ultra-fast 3,5 kW
Natural gas :
G20-20 mbar / G25-25 mbar
Butane gas : G30 28-30 mbar
Propane gas : G31 37 mbar
Jet
122
Jet
122
Jets
102 x 2
Jet
96
Jet
80
Jet
80
Jets
68 x 2
Jet
61
2,5 kW
1,45 kW
3,5 kW
Ultra-
fast
Semi-
fast
Fast
Jet
122
Jets
102 x 2
Jet
96
Jet
80
Jets
68 x 2
Jet
61
2,5 kW
3,5 kW
1,45 kW
Semi-
fast
Fast
4 gas burners
3 gas burners + 1 hot plate
2,5 kW
Fast
Ultra-
fast