- Operations to be carried out to make a new connection:
• Choose the supply cord in accordance with the recommendations in the table
• The oven must be in situation as shown:
• Pass the supply cord into the clamp.
• Strip the end of each conductor of the supply cord a 10 mm length, by taking in account
the cord for the connection on the terminal block.
• According to the installation and with the help of should have recovered in the first
operation, fix the conductor as shown on the chart.
• Engage the earth wire yellow/green on the earth terminal, tighten the nut and verify the
continuity of the earth.
• Secure the cable clamp.
• Fix the cover.
CABLE
Area
3 G 2,5 mm
3 G 2,5 mm
Connection to
the terminal
block
PH
N
E
PH N
E
To shunt : make
a bridge with a
shunt bar
1 rst Phase
Shunt 1-2
Shunt 2-3
Neutral
Shunt 4-5
Earth
1 rst Phase
Shunt 1
Neutral
Shunt 2
Earth
IMPORTANT: Blue wire = Neutral Yellow/green wire = Earth
For the connection to the terminal block, you must:
• respect the n° 1,2,3,4, and 5,
• tighten the screws,