Operation settings, Settings, Cleaning, care and maintenance – STIEBEL ELTRON psh 30 trend User Manual
Page 18: Troubleshooting, 1 holiday and absence

oPerATion
Settings
18
| PSH Trend www.stiebel-eltron.com
4. settings
The temperature can be freely adjusted.
max
D
00000
37
146
2
1
1
ON/OFF indicator
2
Temperature selector
*
Frost protection
E
Recommended energy saving position, low scaling, 60 °C
Max Maximum temperature setting, 75 °C
Depending upon the system, the actual temperatures may vary
from the set value.
on/oFF indicator
The ON/OFF indicator illuminates when water is being heated.
4.1 Holiday and absence
f
f If the appliance is not to be used for a few days, set the tem-
perature selector to a position between the frost protection
and energy saving settings.
f
f If the appliance is not to be used for a longer period, set it to
frost protection to conserve energy. If there is no risk of frost
you may disconnect the appliance from the power supply.
f
f For reasons of hygiene, heat up the content of the water
heater once to above 60 °C before initial use.
5. cleaning, care and maintenance
f
f Have the electrical safety of the appliance and the function of
the safety valve regularly checked by a qualified contractor.
f
f Have the protective anode initially checked by a qualified
contractor after the first year. The qualified contractor will
then determine the intervals at which it must be checked
thereafter.
f
f Never use abrasive or corrosive cleaning agents. A damp
cloth is sufficient for cleaning the appliance.
scaling
f
f Almost every type of water will deposit lime at high temper-
atures. This settles inside the appliance and affects both the
performance and service life. The heating elements must
therefore be descaled from time to time. A qualified contrac-
tor who knows the local water quality will tell you when the
next service is due.
f
f Check the taps/valves regularly. You can remove limescale
deposits at the spouts using commercially available descaling
agents.
f
f Regularly activate the safety valve to prevent it from becom-
ing blocked e.g. by limescale deposits.
6. troubleshooting
Problem
cause
remedy
The water does not heat
up and the ON/OFF indi-
cator does not illuminate.
There is no power.
Check the fuses/MCBs in
your fuse box.
The water does not heat
up sufficiently and the
ON/OFF indicator illumi-
nates.
The temperature is set
too low.
Select a higher temper-
ature.
The appliance heats,
for example, after large
amounts of DHW have
been drawn.
Wait until the ON/OFF
indicator goes out.
The flow rate is low.
The aerator in the tap or
shower head is scaled up
or contaminated.
Clean and/or descale the
aerator or shower head.
If you cannot remedy the fault, notify your qualified contractor. To
facilitate and speed up your enquiry, please provide the numbers
from the type plate (000000 and 0000-000000):
E-NO.: 000000
F-NO.: 0000-000000
D
00000
3
7
1
4
9