Gb operating instructions fan heater hc 200 ts – Dimplex HC 200 TS User Manual
Page 3
3
1. Important Information
Keep these instructions in a safe place and pass them on to
possible future owners.
• Use device for room heating within enclosed rooms only.
• Repairs and corrective measures may only be carried out by
skilled technicians.
• Disconnect the power supply in the event of fault (pull out
the device plug or switch off the fuse).
• Do not use this device next to the bathtub, shower,
washbasin or swimming pool.
• The device carries the symbol shown on the right,
which indicates that the heating device must under
no circumstances be covered with any objects.
• Children or persons who are not capable of
operating the device safely must not operate the heating
device. Ensure that children do not play with the device.
• Caution! Potential dangers can arise when the device
switches on automatically, e.g. devices which have been
covered or blocked by objects since they were last used can
cause fire.
• Do not operate the heating device in rooms where highly
flammable substances are used (e.g. solvents, etc.).
• Do not lay the connecting cable across the device.
2. Technical Device Description
Heat output: 2000 W
Degree of protection: IP21
Connection voltage:
1/N~, 230-240 V, 50 Hz
Dimensions in mm:
(W x H x D) 185 x 258 x 185
3. Installation
Do not cover the heating device with any objects; fire hazard!
The fan heater may only be used as shown, i.e. on a horizontal,
even surface. Using it on deep pile carpets is not permitted.
Please use caution when installing it in front of flammable
objects. The power plug must always be accessible.
Observe the minimum clearances.
4. Electrical Connection
The voltage information on the type plate must match the local
mains voltage.
When the power cord of this device is damaged, it must be
replaced by a qualified person, in order to avoid risks.
5. Operation
The room temperature is regulated using the continuously
adjustable thermostat.
If the rotary knob is set to the smallest setting i.e. to the
extreme left (see figure), the thermostat switches the heating
device on at an ambient temperature of approx. 5°C.
Using the operating mode rotary knob, two heating levels and
a cold air level can be selected. In the cold air fan operation,
turn the thermostat rotary knob to the right stop.
The indicator lamp is lit, when the device is in operation.
Warning!
Depending on the size of the room, heat requirement and
thermostat setting, rooms may overheat if the heating is not
controlled. This can be dangerous for people who are not able
to leave the room as it gets too hot.
6. Protection Against Overheating
If the permissible temperature is exceeded, the fan heater
switches off automatically. When this happens, pull out the
plug and remove the cause (e.g. when the air grid is blocked or
covered). When the device has cooled sufficiently, it can be
started up again.
7. Faults
In the event of faults, please contact your electrical retailer. If
required, you can also address your queries to the service
hotline of Glen Dimplex Deutschland GmbH.
Tel.: +49 (0) 9221 709-564
Fax: +49 (0) 9221 709-589
To process your order, please state the device type as well as
its production number (E-Nr.) and manufacturing date (FD).
This information is listed on the type plate.
8. Cleaning
To clean the device, it must be disconnected from the mains
and allowed to cool down. Clean the outside of the unit using a
soft, damp cloth. Do not use scouring powder or furniture polish
as this may damage the surface. Dust which gathers inside the
device can be removed from the outside using a vacuum
cleaner.
9. Warranty
This product is supplied with a two-year warranty according to
our terms of guarantee.
10. Note on Disposal
Do not dispose of the unit with general household
waste. The device must be taken to a local waste
disposal plant.
GB
Operating Instructions
Fan Heater
HC 200 TS
Glen Dimplex Deutschland GmbH
hc200-en_ba 02/11/A
Am Goldenen Feld 18
www.dimplex.de
D-95326 Kulmbach