beautypg.com

Declaration of conformity, In the european union – Xerox Phaser 7300 User Manual

Page 25

background image

Regulatory Information

Phaser® 7300 Color Printer

22

Declaration of Conformity

Xerox Corporation, declares, under our sole responsibility that the printer to which this declaration
relates, is in conformity with the following standards and other normative documents:

In the European Union

following the provisions of the Low Voltage Directive 73/23/EEC and its amendments:

following the provisions of the Electromagnetic Compatibility Directive 89/336/EEC and its
amendments:

This product, if used properly in accordance with the user's instructions is neither dangerous for the
consumer nor for the environment.

A signed copy of the Declaration of Conformity for this product can be obtained from Xerox.

EN 60950 (IEC 950)

"Safety of Information Technology Equipment including Electrical Business

Equipment"

EN55022:1998
(CISPR 22)

"Limits and Methods of measurement of radio interference characteristics of
Information Technology Equipment." Class B.

EN61000-3-2:1995
+A1:1998+A2:1998.
(IEC61000-3-2)

"Part 3: Limits - Section 2: Limits for harmonic current emissions (equipment

input current less than or equal to 16

A per phase)."

EN61000-3-3:1995
(IEC61000-3-3)

"Part 3: Limits - Section 3: Limitation of voltage fluctuations and flicker in low-

voltage supply systems for equipment with rated current less than or equal to

16

A."

EN55024:1998
(CISPR 24)

"Information technology equipment - Immunity characteristics - Limits and

methods of measurement. "

CISPR 24 Immunity Phenomena

Basic Standard

Test Specification

Electrostatic Discharge

IEC61000-4-2:1995

6

kV Contact, 10 kV Air

Radio-Frequency Electromagnetic

Field (radiated)

IEC61000-4-3:1995

80-1000 MHz, 3

V/m, 80% AM @ 1 kHz

Fast Burst Transients

IEC61000-4-4:1995

5/50 Tr/Th ns, 5

kHz Rep. Freq

0.5

kV on Signal Lines

1

kV on AC Mains

Line Surge

IEC61000-4-5:1995

Combination wave
2.0

kV Common mode

2.0

kV Differential mode

Radio-Frequency Electromagnetic

Field (Conducted)

IEC61000-4-6:1996

0.15 - 80 MHz, 3

V, 80% AM @ 1 kHz

Line voltage dips

IEC61000-4-11:1994

>95% dip for ½ cycle @ 50 Hz
30% dip for 25 cycles @ 50 Hz

Line voltage drop-out

IEC61000-4-11:1994

>95% dropout for 250 cycles @ 50 Hz