4 advanced features, History data – Xantrex Technology Xantrex Battery Monitor User Manual
Page 21
12
4 Advanced Features
Besides the general functionality as described in the previous
chapter, the Xantrex Battery Monitor offers some additional
advanced features. These features are reviewed in the next three
sections.
History data
The Xantrex Battery Monitor is able to store “special” events as
history data in its memory. The following events are stored as history
data:
STATE OF CHARGE BAR GRAPH.
This bar represents the state of charge
in five steps until the “discharge floor”
(see Function F05) is reached. Five bar
segments represent a fully charged
battery. When the battery is
discharged, the bar disappears and the
message “CHARGE BATTERY” will
appear.
H01
The automatically calculated charge efficiency factor
(CEF).
H02
The average discharge in Ah. This value will be
recalculated after each synchronization.
H03
The deepest discharge in Ah.
H04
Number of charge/discharge cycles.
H05
The number of “synchronizations.” This is the number
of times the battery is fully charged meeting the charged
parameters condition.
H06
The number of full discharges (reaching a state-of-
charge of 0.0%).
H07
The number of under-voltage alarms.
H08
The number of over-voltage alarms.