beautypg.com

Xantrex Technology Link 2000 User Manual

Page 28

background image

Troubleshooting Reference

975-0343-01-01

3-3

Charging
Error E02
Overcharge
Shutdown

Battery model being
charged is 18 V or above

Check battery being connected.
This charger will recharge 12 V
batteries only. Use appropriate
charger for your battery

Charging
Error E03
High Current
Shutdown

High current load is
connected to the battery

Remove all loads from the
battery being charged

Charging
Error E04
Overheat
Shutdown

Unit has overheated due to
poor ventilation or
excessively warm
environmental conditions

Clear blocked ventilation
openings or remove objects
covering the unit. Unit will
automatically restart when it
cools down

Move the Duracell® Charger to
a cooler environment

Charging
Error E05
Charging Time
Off

Battery charging time
reaches 24 hours

Charging rate selected for
battery charging is too low
for the battery being
charged

Battery has a damaged cell

Check load is connected to
battery

Select a higher charging rate (see
Table 2-2 on page 2-5)

Replace battery

Table 3-1 Troubleshooting reference

Problem

Possible Cause

Solution

Duracell_Charger15.book Page 3 Friday, June 15, 2007 2:34 PM