Charging
Error E02
Overcharge
Shutdown
Battery model being
charged is 18 V or above
Check battery being connected.
This charger will recharge 12 V
batteries only. Use appropriate
charger for your battery
Charging
Error E03
High Current
Shutdown
High current load is
connected to the battery
Remove all loads from the
battery being charged
Charging
Error E04
Overheat
Shutdown
Unit has overheated due to
poor ventilation or
excessively warm
environmental conditions
Clear blocked ventilation
openings or remove objects
covering the unit. Unit will
automatically restart when it
cools down
Move the Duracell® Charger to
a cooler environment
Charging
Error E05
Charging Time
Off
Battery charging time
reaches 24 hours
Charging rate selected for
battery charging is too low
for the battery being
charged
Battery has a damaged cell
Check load is connected to
battery
Select a higher charging rate (see
Table 2-2 on page 2-5)
Replace battery
Table 3-1 Troubleshooting reference