Charger cable storage compartment, Figure 1-2 duracell® charger storage compartment – Xantrex Technology Link 2000 User Manual
Page 17
![background image](/manuals/230883/17/background.png)
1-6
Charger Cable Storage Compartment
Figure 1-2 Duracell® Charger Storage Compartment
Panel
Item Description
1
Battery Charging Clips for charging your vehicle
battery.
2
Storage Compartment for AC cable and battery clips.
3
Error Code Reference Table provides quick battery
troubleshooting.
4
AC Cable connects the Duracell® Charger to the AC
wall socket.
BAD BATTERY SHUTDOWN Battery is not accepting charge or
battery charge rate is low
• Select a higher charge rate
• For flooded bat tery, activate the battery
reconditioning feature (see Owner's Guide)
Battery model being charged is
18V or above
• Check battery being connect ed. XPower will
recharge 12V batteries only. Use
appropriate charger for your battery.
High current load is connected to
the batter y
• Remove all loads from battery being
charged.
Unit is overheated due to poor
ventilation
• Ensur e vent openings ar e not obstructed.
Unit will automatically r eset.
Charging t ime reached 24 hours • Check load is connected to battery
• Select higher charge rat e
• Battery has damaged cells and cannot be
charged. Replace battery.
EO1
OVERVOLTAGE
EO2
HIGH CURRENT SHUTDOWN
EO3
OVERHEAT SHUTDOWN
EO4
CHARGING TIME OFF
EO5
ERRO R
CO DE
CHARG IN G
ERRO R
PO SSIBLE CAUSE
RECO MMEN DATIO N
1
2
3
4
Duracell_Charger15.book Page 6 Friday, June 15, 2007 2:34 PM