Product identifica tion number (pin), Options model number – York YCAL0080SC User Manual
Page 8
YORK INTERNA
TIONAL
8
PRODUCT IDENTIFICA
TION NUMBER (PIN)
EXAMPLES:
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
XXXXXXXX
L
XXXXXXXXXXXXXXXXXAXXXXXXXXXXXXX
S
D
TC
A
T
S
R
L
X
P
R
S
2
5
C
X
1
XXXX
3
D
W
S
A
R
XBXX
4
BXX
L
X
S
D
OPTIONS MODEL NUMBER
MP = Multiple Point
SP = Single Point
NF = Non-Fused
TB = Terminal Block
Ser. = Service
Ind. Sys. Brkr. & L. Ext. Handles = Individual
System
Breaker & Lockable External
Handle
: Aluminum
: Copper
: Black Fin
: Phenolic
: TEAO Fan
Motors
EVAP. FIELD
CONDENSER FIELD
CABINET FIELD
: Wire Condenser Headers Only (factory)
: Wire (Full Unit) Enc. Panels (factory)
: Wire (Full Unit) Enc. Panels (field)
: Wire/Louvered Enc. Panels (factory)
: Wire/Louvered Enc. Panels (field)
: Louvered (Cond. Only) Enc. Panels (factory)
: Louvered (Cond. Only) Enc. Panels (field)
: Louvered (Full Unit) Enc. Panels (factory)
: Louvered (Full Unit) Enc. Panels (field)
: Acoustic Sound Blanket
: Low Sound Fans
: 1" Deflection
: Seismic
: Neoprene Pads
55
EXTENDED FIELD
X
B
C
D
E
F
G
H
: 1st Year Parts Only
: 1st Year Parts & Labor
: 2nd Year Parts Only
: 2nd Year Parts & Labor
: 5 Year Compressor Parts Only
: 5 Year Compressor Parts & Labor Only
: 5 Year Units Parts Only
: 5 Year Unit Parts & Labor
NOTES:
1. Q :DENOTES SPECIAL / S.Q.
2. #
:DENOTES STANDARD
3. X :w/in OPTIONS FIELD, DENOTES NO OPTION SELECTED
4. Agency Files (i.e. U.L. / E.T.L.; C.E.; ARI; ETC.) will contain info. based on the first 14 characters only.
38 39 40 41 42 43 44
45 46 47
48 49 50 51 52 53 54
3
X
x
D
C
1
W
B
2
V
P
3
S
X
4
A
5
6
R
7
8
B
L
1
S
N
: Low Ambient Kit (factory)
: High Ambient Kit (factory)
: Both Low / High Ambient (factory)
: BAS/EMS Temp. Reset / Offset
: Spanish LCD & Keypad Display
: French LCD & Keypad Display
: German LCD & Keypad Display
: Discharge Pressure Transducers/
Readout Kit
: Suction Pressure Transducers /
Readout Kit
: Both Discharge & Suction Pressure
Transducers / Readout
: N. American Safety Code
(cU.L./cE.T.L.)
: No Listing (typically 50 HZ non-C.E.,
non-U.L.
: Remote Control Panel
: Sequence Control & Automatic
Lead Transfer
16 17 18 19
20 21 22 23 24 25 26 27 28
29 30 31 32 33 34 35 36 37
POWER FIELD
CONTROLS FIELD
COMPRESSOR / PIPING FIELD
X
X
L
#
#
X
X
H
S
X
A
C
S
D
T
B
X
S
F
G
1
T
I
C
R
E
S
B
L
N
C
R
S
:Leaving Supply Temp.
:Chicago Relief Code
:Hot Gas By-Pass
(# circuits)
:Compressor External
Overload
: 300 PSIG DWP Waterside
: Double Thick Insulation
: Weld Flange Kit
: Victaulic Flange Kit
: Flow Switch
: ASME Pressure Vessel &
Associated Codes
: Remote DX Cooler
: SP Supply TB
: MP Supply TB
: SP Supply TB
: SP NF Disconnect Switch
: SP Circuit Breaker w/ Lockable Handle
: Control Transformer (factory)
: Power Factor Capacitor