Clear faults, Clear faults –17 – Xantrex Technology Automatic Generator User Manual
Page 65

The Auto Gen Start Menu
975-0082-01-01
3–17
When to use
Use this setting after installing the Auto Gen Start. Selecting a suitable 
“Gen Type” automatically configures the Auto Gen Start to work with the 
ignition system and starting requirements of your generator. If you are not 
sure of your generator’s requirements, please consult your generator 
manual or contact your generator’s manufacturer.
Outcomes
Selecting a “Gen Type” from the list automatically configures the 
following settings:
•
Preheat time
•
Preheat end to crank delay time
•
Crank time
•
Crank retry time
•
Starter cooldown time
•
Generator Run Signal hold time
•
Start tries.
If your type of generator is not listed under “Gen Type”, you may need to 
manually configure some of the settings listed above (available on the 
Auto Gen Start advanced menu) using information from your generator 
manufacturer.
Clear Faults
Purpose
“Clear Faults” clears all active Auto Gen Start faults. To clear the active 
faults, highlight Clear Faults and press Enter. For more information about 
how the Auto Gen Start treats faults and fault messages, see “Faults and 
Warnings” on page 5–2.
Type 10
General
StartStop
Type 11
Kohler
MomentaryRun
Type 12
Onan Propane
GlowStop with no preheat
Type 13
PowerTech Diesel
PulseStop with Relay 3 preheat
Option
Description
Configuration
Mode