Configuration
3–12
975-0082-01-01
Use the Quiet Time feature to ensure that the generator will not run during 
the night, or to comply with “Quiet Time” guidelines at RV parks and 
campgrounds.
To use the Auto Gen Start Quiet Time feature, first set “QT Enable” to 
On, then set two times of the day or night (a Quiet Time Begin time and a 
Quiet Time End time) to define a time interval during which the generator 
will not run.
To disable the Quiet Time feature, set “QT Enable” to Off.
Time zone
When travelling between time zones, ensure that you set the clock on the 
System Control Panel to your correct local time. Otherwise, your quiet 
time settings will come into effect too early or too late.
Battery drain
Quiet Time prevents the automatic starting of the generator regardless of 
battery condition.
If you need to set a quiet time that lasts overnight, be aware that overnight 
battery drain can be significant. Because you may need to use an inverter 
and batteries to supply AC power during quiet time, be careful to 
conserve battery power. Minimize the use of interior lights and set 
thermostat temperature lower to prevent the furnace from coming on at 
night during cool weather. Set thermostats higher to prevent air 
conditioning coming on at night during warm weather.
Outcomes
Sometimes automatic start or automatic stop triggers may overlap with 
the beginning and end of quiet time. Three different quiet time scenarios 
affect when the generator stops and starts.
1. If quiet time begins after the Auto Gen Start has started the generator,
the generator will stop. If the condition that started the generator is 
still present when quiet time ends, the generator will restart.
2. If a condition that requires starting the generator occurs during quiet
time, the Auto Gen Start will ignore it until quiet time ends. If the 
condition still exists at the end of quiet time (after the time you set for 
“QT End”), the Auto Gen Start will start the generator.
3. If the running generator stops when quiet time begins and a condition
that requires stopping the generator occurs during quiet time, the 
generator will not restart when quiet time ends.