036-21528-001-A-0303

Unitary Products Group

3

PROTECTED COMPRESSOR

The compressor is internally protected against high

pressure and temperature. This is accomplished by the

simultaneous operation of high pressure relief valve

and a temperature sensor which protects the compres-

sor, if undesirable operating conditions occur.

EXCLUSIVE COIL DESIGN

Grooved copper tubes and enhanced aluminum fin

construction improves heat transfer for maximum effi-

ciency and durability.

LOW MAINTENANCE

Long life, permanently lubricated condenser and evap-

orator fan motor bearings, need no annual mainte-

nance. Blower assembly can be easily cleaned by the

unique ìSlip Trackî slide-out blower assembly.

SECURED SERVICE ACCESS PORTS

Protected, externally mounted, re-usable service

access ports are provided on both the high and low

lines for ease of evacuating and charging the system.

EASY SERVICE ACCESS

A large, single hinged panel covers the electrical con-

trols and makes servicing easy. The blower compart-

ment has an additional large panel with a built-in

handle tab. Removing this panel will allow the blower

assembly to slide-out for easy removal for mainte-

nance and ease of trouble shooting.

REPLACEMENT PARTS

The installer has no need to carry an inventory of

unique parts or needs special training to replace any of

the components parts for these units. All are easily

obtained from Source 1 or other major part houses.

FIELD-INSTALLED ACCESSORIES

ECONOMIZER DOWN DISCHARGE / SUPPLY KIT

Modulating integrated economizer provides simulta-

neous operation between the mechanical cooling and

economizer operation. Independent blade design

insures proper control and less than 1% leak rate.

Includes hood and mesh bird screen filter integrated

into the hood, dry bulb sensor and relief damper. Sepa-

rate field accessories of single enthalpy and dual

enthalpy are also available.

SINGLE ENTHALPY SENSOR

Sensor replaces dry bulb sensor standard in econo-

mizer kit. Provides improved economizer operation by

sensing the dry bulb temperature from outdoors, plus

the enthalpy content of the outdoor air.

DUAL ENTHALPY SENSOR

Additional sensor to single enthalpy sensor. Sensor

selects both the return air temperature dry bulb and
humidity, in conjunction with the single enthalpy, to

determine the most economical mix. Single Enthalpy

sensor also required.

UPGRADE PRESSURE PACKAGE

Contains screw in type High pressure, Low Pressure/

Loss of Charge switch, freeze protection switch and

lockout relay. Switches are placed onto existing

Schrader ports located in the unit by furnished adapt-

ers. When abnormal conditions are sensed through the

pressure switches, the unit will lock out, preventing any

further operation until reset or problem is corrected.

Package agency approved.

HAIL GUARD KIT

Kit contains protected grilles made of expanded alumi-

num grilles with full perimeter 1-1/2 inch frame. Sloped

hoods are also included to assure maximum protec-

tion.

FILTER / FRAME KIT (SINGLE PHASE ONLY)

Kit contains the necessary hardware to field install

return air filters into the base unit. Pre-cut filter racks

and appropriate cleanable standard size filters are

shipped in one kit (1" filter is supplied). This kit is avail-

able for single phase horizontal or vertical duct applica-

tion only. Standard in all 3 Phase models.

MOTORIZED FRESH AIR DAMPER

Designed for duct mounted side return and unit

mounted down shot return applications. Damper capa-

ble of providing 0% thru 50% of outdoor air (field sup-

plied). Closes on power loss, includes hood and screen

assembly.