Table 15: electrical data (basic unit) – York B1HP024 THRU 048 User Manual
Page 16
036-21528-001-A-0303
16
Unitary Products Group
TABLE 15: ELECTRICAL DATA (BASIC UNIT)
MODEL
BHP
POWER
SUPPLY
VOLTAGE
LIMITATIONS
1
COMPRESSOR
OUTDOOR
FAN
MOTOR,
FLA
SUPPLY AIR
BLOWER
MOTOR,
FLA
MINIMUM
CIRCUIT
AMPACITY
MAX
FUSE
SIZE,
AMPS
2
MAX.
HACR
BREAKER
SIZE,
AMPS
UNIT
POWER
FACTOR
TRANSFORMER
SIZE (VA)
MIN.
MAX.
RLA
LRA
024
208/230-1-60
187
253
9.3
57.0
1.1
5.0
17.7
25
25
0.96
40
030
208/230-1-60
187
253
15.0
72.5
1.1
5.0
24.9
35
35
0.96
40
208/230-3-60
187
253
10.0
63.0
1.1
5.0
18.6
25
25
0.96
75
460-3-60
414
504
5.0
31.0
0.6
5.0
11.9
15
15
0.96
75
036
208/230-1-60
187
253
17.2
94.0
1.1
7.3
29.9
45
45
0.96
40
208/230-3-60
187
253
11.4
78.0
1.1
7.3
22.7
30
30
0.96
75
460-3-60
414
504
5.7
40.0
0.6
7.3
15.4
20
20
0.96
75
042
208/230-1-60
187
253
20.0
104.0
1.1
7.3
33.4
50
50
0.96
40
208/230-3-60
187
253
13.9
88.0
1.1
7.3
25.8
35
35
0.96
75
460-3-60
414
504
6.4
44.0
0.6
7.3
16.1
20
20
0.96
75
048
208/230-1-60
187
253
23.4
126.0
1.5
7.3
38.1
60
60
0.96
40
208/230-3-60
187
253
13.0
93.0
1.5
7.3
25.1
35
35
0.96
75
460-3-60
414
504
6.4
46.5
0.8
7.3
16.3
20
20
0.96
75
1.
Rated in accordance with ARI Standard 100, utilization range ìAî.
2.
Dual element, time delay type.
ELECTRIC HEAT
CORRECTION
FACTORS
NOMINAL VOLTAGE
VOLTAGE KW CAP. MULTIPLIER
240
208
230
0.75
0.92
480
460
0.92