Troubleshooting the Ethernet Connection and Adapter
5.
If the LED is alternately flashing
red
and
green
for longer than 2 minutes, the Ethernet
Adapter is in firmware-download mode. This means it is waiting for new firmware data to
be sent before it continues normal functioning. Perform the following:
•
• Contact Technical Support for help recovering this unit.
Network Status/Activity Indicator
A bi-color Status/Activity LED indicates network speed, established link, and network
activity.
1.
If the LED is off, no link was established.
2.
If the LED is solid
green
, a 100Base link is established.
3.
If the LED is flashing
green
, a 100Base link is established and network activity has been
detected.
4.
If the LED is solid
orange
, a 10Base link is established.
5.
If the LED is flashing
orange
, a 10Base link was established and network activity has
been detected.
Network activity detected by this LED does not mean the activity is data for the print server.
The activity is all activity on the network seen on the Ethernet Adapter.