XEROX Trade Name: ECP-Magenta Toner Premix/Concentrate for ECP 42

MSDS No.: A-2006

A

Section IV - Physical Data


Appearance/Odor:

Magenta liquid /slight odor

Softening Range: N.A.

Boiling Point: 160

-180

oC

Melting Point: N.A.

Solubility in Water: Immiscible

Specific Gravity (H2O=1): 0.77

Evaporation Rate:

0.3, (n-Butylacetate = 1)

Vapor Pressure @20oC (mm Hg):

1

Vapor Density (Air=1): 5.0

pH: N.A.

Volatile:

~100% (Wt.) N.A. % (Vol.)

Volatile Organics:

660- 730 g/l


Section V - Fire and Explosion Data


Flash Point (Method Used): 102o-107oF (39-42oC) T.C.C.
Flammable Limits

LEL: 0.8%, UEL: 7.0%

NFPA 704:

Health - 1, Fire - 2, Reactivity - 1

Extinguishing Media:

Foam, dry chemical, CO

2

, water fog.

Special Fire Fighting Procedures: Use air-supplied breathing equipment for enclosed areas. Cool exposed containers with water

spray. Avoid breathing vapor or fumes.

Fire and Explosion Hazards:

Do not mix or store with strong oxidants like liquid chlorine or concentrated oxygen.


Section VI -Reactivity Data


Stability:

Stable

Hazardous Polymerization:

Will Not Occur

Hazardous Decomposition Products: Fumes, smoke and carbon monoxide in the case of incomplete combustion.
Incompatibility (Materials to Avoid): Strong oxidants such as liquid chlorine, concentrated oxygen, sodium/calcium hypochlorite.

Section VII - Special Protection Information


Respiratory Protection:

None when used as intended with Xerox Engineering Systems products.

Eye Protection:

None when used as intended with Xerox Engineering Systems products.

Protective Gloves:

Neoprene or nitrile gloves for prolonged or repeated skin contact.

Other:

None when used as intended with Xerox Engineering Systems products.


Section VIII - Special Precautions


Handling and Storage: Keep container closed. Avoid handling near heat, strong light, sparks, oxygen flames, strong oxidants.
Conditions to Avoid:

Avoid breathing vapors. Avoid prolonged or repeated skin contact.


Section IX- Spill, Leak, and Disposal Procedures


For Spills or Leakage:

Remove ignition sources. Recover free liquid using an absorbent material (vermiculite, fire

retardant, sawdust, etc.).

Waste Disposal Method:

The waste toner may be classified as an ignitable hazardous waste under federal and/or state

regulations and should be disposed at an approved disposal site or facility in accordance with federal,

state, and local regulations.


Section X - Transportation Information


Proper Shipping Name

Hazard Class

ID #

Packing Group Exceptions may apply

D.O.T

Combustible liquid, n.o.s.

Combustible

NA

1993 III

Reclassification: 49CFR 173.150 (f) (2) *

(Isoparaffinic hydrocarbon)

liquid

I.A.T.A

Flammable liquid, n.o.s.

3

UN 1993

III

Y309.

(Isoparaffinic

hydrocarbon)

I.M.O

Flammable liquid, n.o.s.

3 UN

1993

III

3.4 Limited Quantities

(Isoparaffinic

hydrocarbon)


*Note: This product has been reclassified as a combustible liquid under DOT when shipped domestically by land only. This product is not regulated by DOT when
shipped in non-bulk quantities of less than 119 gallons. This product is exempt from the Canadian Transportation of Dangerous Goods regulations (section 1.33), when
transported in containers less than 450 liters and not by air.