UsER INsTRUCTIONs

• Leave the door slightly open as the fire establishes and

the glass warms to avoid the build-up of condensation

• Add larger pieces of wood

Too many logs may smother the fire.

Do not load fuel above the log guard and the secondary

combustion holes at the back of the firebox.

See Diagram 7

Secondary Combustion holes

Log Guard

PR8252

• Close the door

Do not leave the door open as this could over-fire and

damage the appliance

.

5. RUNNING THE APPLIANCE

5.1 Burning Wood (with or without Multi-fuel kit fitted):

• Leave the Secondary Air fully open

• Close the Primary air control and use the Airwash to

control the burn rate when appliance is at operating

temperature, see Diagram 8

Secondary Air:

Fully Open

Primary Air:

Closed

Secondary Air:

Fully Open

Primary Air:

Closed

Air Wash: Fully Open

Air Wash: Fully Open

• Wood burns best on a bed of ash

• Rake the embers evenly over the fire bed and open the

Airwash control

fully for a few minutes before re-fuelling

5.2 Burn new logs at high output for a few minutes before

adjusting the Airwash control. Refuel little and often for

clean, efficient burning.

5.3 Experience establishes settings to suit personal preferences.

5.4 Do not burn large amounts of fuel with the Airwash control

closed for long periods of time. This reduces the glass

cleaning effect and causes tars and creosotes to build-up in

the appliance and flue system.

5.5 When in use, burning the appliance at high output for a

short period also reduces tars and creosote.

5.6 Burning solid fuel (with Multi-fuel kit fitted):

• Set air controls, See Diagram 9

• To burn solid fuel efficiently it is best to control the

combustion using the Primary air control only