Technical specification, Yeoman exmoor/exe/devon/county, Exmoor exe devon county – Yeoman EXMOOR YM-W9001FL User Manual
Page 13: Standard features, Packing list

YEOMAN EXMOOR/EXE/DEVON/COUNTY
13
TECHNICAL sPECIFICATION
MODEL:
Exmoor
– YM-W9001FL / YM-W9001LC / YM-W9001ERFL / YMW9001ERLC
Exe
– YM-W9101FL / YM-W9101LC / YM-W9101ERFL / YMW9101ERLC
YM-W9102FL / YM-W9102LC / YM-W9102ERFL / YM-W9102ERLC
Devon
– YM-W9201FL / YM-W9201LC / YM-W9201HC / YM-W9201ERFL /
YM-W9201ERLC / YM-W9201ERHC / YM-W9202FL / YM-W9202LC /
YM-W9202HC / YM-W9202ERFL / YM-W9202ERLC / YM-W9202ERHC
County
– YM-W9301FL / YM-W9301LC / YM-W9301HC / YM-W9302FL/
YM-W9302LC / YM-W9302HC
Exmoor
Exe
Devon
County
Nominal Heat Output
Wood
kW
4.9
4.9
9
13
Solid Fuel
kW
4.9
4.9
9
13
Flue Draught at Nominal Heat Output
All fuels
mm Wg
1.25
1.25
1.25
1.25
inch Wg
0.05
0.05
0.05
0.05
Flue Gas Mass Flow
Wood
g/s
5.8
4.7
4.9
9.5
Solid Fuel
g/s
3.9
4.8
6.8
7.5
Flue Gas Temperature at Spigot / Socket
Wood
oC
338
394
426
340
Solid Fuel
oC
338
394
426
326
Flue Outlet Size (Top/Rear Option)
mm
125
150
150
150
inch
5
6
6
6
Weight
Kg
65
105
112
160
Recommended Fuels
Wood
Seasoned wood (less than 20% moisture content)
Solid Fuel
Briquette smokeless fuel suitable for closed appliances
(Ancite-Phuracite-Taybrite-Homefire Ovals)
As tested to the requirements of EN 13240 for intermittent operation
sTANDARD FEATUREs
•
Primary air (under grate air for full multi-fuel use)
•
Airwash (for wood burning / clean glass)
•
Adjustable secondary air control (to ensure complete
burning of flue gases)
•
Riddling grate system for clean de-ashing when fitted
with multi-fuel kit (excludes County models)
•
Removable door handle tool
•
Top or rear flue exit option
•
Removable door cross option (2 door only)
•
Rose or plain primary air spinners (1 door only)
PACKING LIsT
•
Instructions
•
Guarantee card
•
Pair leather gloves
•
Door handle tool
•
2 x Baffle extension tubes
•
Cast flue spigot
•
Cast flue blank
•
Pack of fixings