UsER INsTRUCTIONs

3. RECOMMENDED FUELs

3.1 Wood Logs:

• Burn only seasoned timber with a moisture content of less

than 20%

Wood Length

Appliance

Wood Length

Exmoor

250mm

Exe

300mm

Devon

350mm

County

400mm

• Dry cut wood for 12 to 18 months before use

Poor quality timber:

— Causes low combustion efficiency

— Produces harmful condensation

— Reduces effectiveness of the airwash and life of the

appliance

Do not burn construction timber, painted, impregnated /

treated wood, manufactured board products or pallet

wood

.

3.2 solid fuel:

To burn smokeless fuels it is required to fit a cast iron multi

fuel kit. This kit also allows the efficient combustion of

wood.

Multi-fuel kit part numbers:

stove

Part No.

Exmoor

YM-A9040CE

Exe

YM-A9140CE

Devon

YM-A9240CE

County

YM-A9340CE

Only for use with recommended fuels, see Installation

Instructions

for full fitting details.

• Burn only anthracite or manufactured briquette smokeless

fuels listed as suitable for use with closed heating appliances

Do not burn bituminous coal, ‘petro-coke’ or other

petroleum based fuels as this will invalidate the product

guarantee

.

3.3 Fuel consumption.

As tested at nominal heat output to the requirements of EN

13240: 2001 for intermittent operation:

Description

Fuel Consumption

Kg/Hour

Wood

(300mm long)

Kg/Hour

Briquette

smokeless Fuel

Exmoor

1.7

0.7

Exe

1.7

0.7

Devon

2.7

1.5

County

3.9

2.1

3.4 For advice on suitable solid fuels:*

• Contact your local approved coal merchant

A number of factors can affect the performance of the

appliance. See Section 6 'Burning Tips' for details.

4. LIGHTING THE APPLIANCE

4.1 For best results:

• Set air controls, See Diagram 5

Secondary Air:

Fully Open

Primary Air:

25% Open

Secondary Air:

Fully Open

Primary Air:

25% Open

Air Wash:

Fully Open

Air Wash:

Fully Open

• Place firelighters or paper and dry kindling wood on the

grate

• Light the paper or firelighters, See Diagram 6

*In the U.K:

• Ring the Solid Fuel Association advice line on

0845 601 4406 for details