OPERATION

Emergency System

EMER bypasses the Heat Pump to use the heat source wired
to terminal W2 on the thermostat. EMER is typically used when
compressor operation is not desired, or you prefer back-up
heat only.

1. Move SYSTEM switch to EMER position, EMER will fl ash

on the display.

2. Press

to adjust the thermostat above room temperature.

The Aux heating system will begin to operate. The Flame
icon
( ) will display fl ashing to indicate that the Aux system
is operating.

3. Press

to adjust the thermostat below room temperature.

The Aux heating system should stop operating.

Cooling System

1. Move SYSTEM switch to COOL position.

2. Press

to adjust thermostat setting below room

temperature. The blower should come on immediately on
high speed, followed by cold air circulation.

3. Press

to adjust temperature setting above room

temperature. The cooling system should stop operating.

To prevent compressor and/or property damage, if the
outdoor temperature is below 50

o

F, DO NOT operate

the cooling system.

CAUTION

!

CHECK THERMOSTAT OPERATION

If at any time during testing your system does not operate
properly, contact a qualifi ed service person.

Turn on power to the system.

Fan Operation

If your system does not have a G terminal connection, skip to
Heating System.

1. Move fan switch to ON position. The blower should begin to

operate.

2. Move fan switch to AUTO position. The blower should stop

immediately.

Heating System

1. Move SYSTEM switch to HEAT position. If the auxiliary

heating system has a standing pilot, be sure to light it.

2. Press

to adjust thermostat setting to 1° above room

temperature. The Heat Pump system should begin to
operate. However, if the setpoint temperature is fl ashing, the
compressor lockout feature is operating (see Confi guration
menu, item 6).

3. Adjust temperature setting to 4

o

above room tempe

rature.

The auxiliary heat system should begin to operate and the
Flame icon will be fl ashing.

4. Press

to adjust temperature setting below room

temperature. The heating system should stop operating.

Do not allow the compressor to run unless the
compressor oil heaters have been operational for 6
hours and the system has not been operational for at
least 5 minutes.

CAUTION

!