Installer/configuration menu – White Rodgers BLUE 2 1F89-0211 User Manual
Page 5

5
4) Select Compressor Lockout CL OFF or ON - Selecting
CL On will cause the thermostat to wait 5 minutes between
cooling cycles. This is intended to help protect the
compressor from short cycling. Some newer compressors
already have a time delay built in and do not require this
feature. Your compressor manufacturer can tell you if the
lockout feature is already present in their system. When the
thermostat compressor time delay occurs, it will fl ash the
setpoint for up to fi ve minutes.
5) Select Backlight Display - The display backlight improves
display contrast in low lighting conditions. When the “C”
terminal is connected, selecting backlight CdL On will keep
the light on continuously. Select backlight OFF will turn the
light on momentarily when any key is pressed. When the
“C” terminal is not connected, regardless of the backlight
selection, the light will be on momentarily when any key is
pressed.
6) Select Temperature Display Adjustment 4 LO to 4 HI -
Allows you to adjust the room temperature display up to 4°
higher or lower. Your thermostat was accurately calibrated
at the factory but you have the option to change the display
temperature to match your previous thermostat. The
current or adjusted room temperature will be displayed on
the display.
7) Select F° or C° Readout - Changes the display readout to
Celsius or Fahrenheit as required.
8) Select Fast Second Stage ON or OFF - (Heat Pump Only)
In the HEAT mode, with the Fast Heat feature enabled (FH
Heat On), if the temperature is manually raised by 3°F (2°C)
or more above the actual temperature using the
, the
second stage will energize immediately. With FH OFF, the
thermostat will determine the optimum time (approximately
0 to 30 minutes) to use Auxiliary/Second stage heat in
addition to the Heat Pump.
9) Select Filter Replacement Reminder and Set Run Time
Select the “Change Filter” reminder On or OFF. If selected
On, press
and
to select the time period from 25 to
1975 hours in 25 hour increments. In a typical application,
200 hours (default) of run time is approximately 30 days.
After the selected time of blower operation, the thermostat
will display “Change Filter” as a reminder to change or
clean your air fi lter. When “Change Filter” is displayed,
press the
and
button to clear the display and
restart the time to the next fi lter change. A selection of OFF
will cancel this feature.
Confi guration Menu
Menu
Reference
Number
Press
Key
Displayed
(Factory
Default)
Press
or
to select
from listed op-
tions
Comments
1
and
CS
(OFF)
On
Select Cool Savings Feature On or OFF
and
CS
(3)
1, 2, 3, 4, 5, 6
If CS selected On, selects Cool Savings value
2
and
CR HE-PU
(FA)
SL
Select Adjustable Anticipation, cycle rate, Heat
Pump, Heat and Cool
3
and
CR Aux
(FA)
SL
Select Adjustable Anticipation, cycle rate,
Heat Pump Aux Stage
4
and
CL
(OFF)
On
Select Compressor lockout OFF or On
5
and
L
(On)
OFF
Select Display Light On or OFF
6
and
Temp
(0 HI)
4 LO to
4 HI
Select temperature display adjustment higher
or lower
7
and
o
F
o
C
Select
o
F /
o
C Display (temperature units in
Fahrenheit or Celsius)
8
and
FH
(On)
OFF
Select fast second stage On or OFF
9
and
Change Filter
(OFF)
On
Select fi lter replacement indicator OFF or On
and
Change Filter
(200 h)
25 to 1975
If Change Filter selected On, selects time inter-
val for Change Filter Indicator.
(in 25 hour increments)
10
and
Returns to normal operation
INSTALLER/CONFIGURATION MENU