PT-EXPL5000 060311
Model
5000ti & 5000tir
Cellar Size
1000 cu. ft.
Dimensions
14.25”W x 16”H x 28”D
Weight
96 lbs
AMPS
(running)
9
dBA
54 low 60 med 68 high
Installation
Through-the-Wall, partially ducted, fully ducted
Thermostat
Standard Unit: Dixell XR70CX Remote Version: Dixell XW260K
Temp. Delta
55°F temperature differential
(maintains proper cellar temperature when exhaust environment does not exceed 110°F)
Outside Venting
Can be done if the outside temperature does not exceed 110°F, the external grille
cover is required.
Ducting Options
Unit can be fully ducted.
Warranty
2 year parts and labor / 5 year compressor
FAN SPEED REFERENCE
(Extreme 5000ti or 5000tiR)
UNIT SPECIFICATION
Your fan speed selection will depend on the amount of heat that needs to be removed from the cellar, as well
as the application of the unit (Thru the Wall Installation or Ducted). If the unit is going to be ducted you would
need to use the highest fan speed (The higher fan speed is designed to support the reduction in airflow created
by the ductwork) For the thru the wall application, the fan speed selection will depend on the cellar size, insula-
tion factor, door seal and desired wine temperature. When initially installing the unit, set the fan speed to the
highest setting for a quick chill down. Once the temperature of the cellar reaches the desired temperature, you
may be able to select a lower fan speed to handle the normal load. In the event the temperature outside goes
above 90 degrees, (when exhausting to the outside) you may need to select the higher fan speed.
Speed
CFM
DBA
BTU
Evaporator/Condenser
Low
147
51/51
2967
Medium
180
58/57
3142
High
256
66/65
3360
* To get a feeling for decibels, a food blender at 3ft is 90 dBA, garbage disposal at 3ft is 85 dBA, vacuum cleaner at