beautypg.com

WhisperKool EXTREME 5000TIR User Manual

Page 11

background image

Page 11

Unobstructed Airflow

Unobstructed airflow to and from the unit is a

critical factor in the unit’s overall performance.

Make sure there is a three-foot clearance in the

front of the unit, as fans blow straight out and

should not be obstructed by racking. This will

assure that the unit can move the air around in

an efficient manner. Avoid the attempt to camou-

flage the unit by installing racking in front of the

unit. This will restrict airflow and thus the unit’s

ability to work efficiently.

Mounting the Unit

The unit must be mounted within 18“ of the top

of the room in order to achieve sufficient cool-

ing. As the room cools down, the warm air will

rise to the ceiling. Mounting the WhisperKOOL

high in the room will create a consistently cool

environment by capturing the warm air and

replacing it with cool air. Mounting the unit low

in the room will result in a temperature variation

in the room due to the unit’s inability to draw

warm air from the ceiling of the cellar to the unit

itself, and cold air settling to the floor.

Door and Door Seal

An exterior grade (1 3/4”) door must be

installed as a cellar door. It is very important

that weather stripping is attached to all 4

sides of the doorjam. A bottom “sweep” or

threshold is also required. The door must

have a very good seal to keep the cool cel-

lar air from escaping out of the cellar. One

of the most common problems with cool-

ing units running continually is due to the

door not sealing properly. In cases where

glass doors are used and the room size is

close to the recommended unit size, the

next larger size WhisperKOOL should be

used. This will compensate for the insula-

tion loss due to the lower insulating rating

of glass.

HIGH

MED

LOW

Front of Unit

Exhaust Room

Wine Cellar

Exhaust

Intake

HIGH

MED

LOW

This manual is related to the following products: