TEST THE UNIT PRIOR TO INSTALLATION

To prepare it for testing before installation in wall:

Unit needs to be in the upright position for 24 hours before starting.

Remove unit from box

Place unit on tabletop

Plug in unit to electrical outlet

Plug in bottle sensor

Turn on to test (Should be 10°F- 15°F across coils) approx. 20-30 minutes

Turn off after test

Remove bottle sensor

Electrical Needs

The WhisperKOOL Extreme System requires a dedicated 115-volt 20-amp circuit. The unit draws a large

amount of amps at initial start up. By designating a dedicated circuit breaker, you will guarantee the unit has

enough power to run effectively. Contact an electrician for assistance with the installation of this dedicated

electrical circuit:

1.

Match the electrical outlet to the plug provided on the WhisperKOOL unit.

2.

Provide a dedicated circuit and wiring for the unit.

3.

Provide a weatherproof plug for units connected outside.

Electrical Inlets

The unit is equipped with two power inlets: One is located on the right side of the unit; (inside the cellar) the

other is located on the rear of the unit (outside of the cellar). Use the selector switch located on the right side of

the unit to select which power inlet you would like to utilize. (Meaning if you would like to plug the unit into a

socket outside of the cellar, set the selector switch to rear; if you would like to plug the unit into a socket inside

of the cellar, set the selector switch to the front position. When placed in either position power can only enter

the unit utilizing the power inlet you’ve selected.)

Plug your WhisperKOOL unit into a surge protector or power conditioner. As with any sensitive electrical equip-

ment, the WhisperKOOL electrical equipment may be damaged by power surges and spikes. Power surges and

spikes are not covered in the WhisperKOOL Extreme warranty.

WE RECOMMEND THAT YOU DO NOT USE A GROUND FAULT INTERRUPTER (GFI) WITH THIS PRODUCT.

In case the unit should lose power, press the reset button and attempt to turn the unit back on. Check the home/

main circuit breaker. If the unit does not respond properly, refer to the Troubleshooting section on page 34.

INSTALLATION