TROUBLESHOOTING GUIDE

Solution

Unit should be level in wall to prevent leaking
Check drain line to make sure water can flow freely.
Disconnect drain and clear out, open access door and
check drain for blockage

Fix Drain line so there is a downward slope from the unit to the drain.

Melt ice with blow drier. Soak up with a towel

Solution

Make sure fan is unobstructed; clean evaporator if necessary
Call Customer Service at 800-343-9463
Call Customer Service at 800-343-9463
Shut unit off for 1 hour to allow compressor to cool. Turn

back on and check for cooler air flow out. If compressor

runs, check for and clean condenser coil as possible cause

of compressor overheating. If problem repeats, call cus-

tomer service.

Solution

Call Customer Service at 800-343-9463
Shut unit off for 1 hour to allow compressor to cool. Turn

back on and check for cooler air flow out. If compressor

runs, check for and clean condenser coil as possible cause

of compressor overheating. If problem repeats, call cus-

tomer service.

Solution

Call Customer Service at 800-343-9463
Call Customer Service at 800-343-9463

Solution

Move bottle probe to a more central location.
Call Customer Service at 800-343-9463
Call Customer Service at 800-343-9463
Call Customer Service at 800-343-9463

Solution

Raise the Fon setting to increase the humidity level

Unit leaks water

Possible Cause

Unit is not level

Drain line clogged or kinked

Drain is clogged preventing water form escaping

Drain line does not have a downward slope

Coil is iced causing drain pan ice and water overflowing

Unit runs but does not cool
Possible Cause

Lack of air flow

Compressor not running

Unit undersized

Compressor is overheated

Evaporator fan runs but compressor does not
Possible Cause

Compressor and/or starting components faulty

Compressor may have overheated.

Compressor runs; evaporator fan does not
Possible Cause

Faulty fan motor

Faulty fan relay

Compressor short cycles
Possible Cause

Evaporator blows on bottle probe

Unit low on refrigerant charge

Condensing fan motor/capacitor faulty

Compressor and /or starting components faulty

Humidity in cellar too low
Possible Cause

Not enough moisture