beautypg.com

Wegener Communications UNITY 4600 User Manual

Page 56

background image

Operation

50

800032-01 Rev. G

www.wegener.com

TEST group value

group:

Mnemonic for a test group: Either

RF

,

AV

,

DTMF

, or

REL

.

value:

Parametric value which has meaning depending on the test group selected.

Command to activate Installation Test Modes. A Local Control Command (available from the terminal

regardless of "Local Control Enable/Disable" commands from the network).

If group is

RF

, the legal values are

1

,

2

,

3

,

4

, and

OFF

. Entering numbers for value cause the IRD to report

the RF level (not locked to carrier) at that RF Feed Port every few seconds. Entering

OFF

stops the measurement.

If group is

AV

, the legal values are

ON

and

OFF

. If

ON

, a test pattern is activated on the video output and

test tones activated on the audio output, the same as the generic

TESTMODE

command.

If group is

DTMF

, the legal values are

ON

and

OFF.

If

ON

, the command behaves like the

DTMFVOL

command entered with no parameters

If group is

REL

, the legal values are

ON

and

OFF

. If

ON

, both user cue relays are alternately energized

and de-energized.

TESTOFF

Command stops all volatile test functions as if unit were reset. A Local Control Command (available from

the terminal regardless of "Local Control Enable/Disable" commands from the network).

UNMUTE [source][source][source][...]

source:

Same as the

MUTE

command.

Identical to

MUTE

except specified services are unmuted.

VER

Displays the boot-up Welcome banner and the versions of hardware and software components within

the IRD. Should include the unit serial number, model number, and customer ID. A Local
Control Command (available from the terminal regardless of "Local Control Enable/Disable"
commands from the network).

VBI enable line field

enable:

E

for Enable or

D

for Disable.

line:

Line # where VBI data is normally to be re-inserted. Values below

7

or above

22

are illegal.

field:

Field # where VBI data is normally to be re-inserted. Values are

1

or

2

for upper and lower.

Command enables or disables VBI data re-insertion on the line and field indicated for those IRDs that

support that function.