beautypg.com

Installer/configuration menu – White Rodgers 1F97-1277 User Manual

Page 7

background image

7

18)

Heat Temperature Limit Range – This feature adjusts

the highest setpoint temperature for heat . The default

setting is 99°F . It can be changed between 62°F and

98°F by pressing the or key . The

"temperature

limit" icon will be displayed to the left of your setpoint

temperature when using this feature . The

"temperature

limit"

icon will flash if an attempt is made to adjust the

temperature beyond the range selected .

19)

Cool Temperature Limit Range – This feature adjusts

the lowest setpoint temperature for cool . The default

setting is 45°F . It can be changed between 46°F and

82°F by pressing the or key . The

"temperature

limit"

icon will be displayed to the left of your setpoint

temperature when using this feature . The

"temperature

limit"

icon will flash if an attempt is made to adjust the

temperature beyond the range selected .

20)

Keypad Lockout – This step allows you to select the

type of lockout or limited range security required . If no

lockout or limited range security is required, press to

advance the menu .

Three security settings are available in this menu item .

Use the or keys to select the lockout desired .

Lockout selections are:

"Keypad Lockout and L" = Total Lockout . Total Lockout

locks all keys .

"Keypad Lockout and P" = Partial Lockout . Partial Lock-

out allows only the or keys to operate within your

set temperature limits .

"Temperature Limit/Keypad Lockout" prevents

changing the temperature limits in the Configuration

Menu .

Keypad Lockout Combination Number Selection

Display will read

"OFF" "Keypad Lockout" .

Skip this step and continue through the configuration

menu items 21 thru 22 if you require an Air Filter Change

out indicator or Humidifier Pad Change out indicator by

INSTALLER/CONFIGURATION MENU

pressing the button to advance .

Return to this point when you are ready to start your

selected lock-out and continue by:

Pressing or keys to select ON .

Press . Display will read

"000" .

Pressing or keys to select your keypad lockout

combination number . Note:

"000" is not a valid

combination choice .

Record the number you select for future use.

Press to exit the menu . The security feature you

select will start in 10 seconds . The system button will

remain active for 10 seconds to allow setting Heat, Off,

Cool or Auto .

21)

Select Remote Temperature Sensor – This control

allows one wired remote temperature sensor (indoor or

outdoor) be connected to it and indicates the measured

temperature in clock digits . This menu enables you to

select the remote sensor and also configure it as indoor

or outdoor temperature sensor . Factory default is off .

Select

Remote On and Remote in (for indoor) or

Outdoor Remote .

Local Temperature Sensor disable – This is applicable

only when indoor remote temperature sensor is enabled .

Factory default is

On LS . You can make it Off LS if you

desire by using or touch keys . Then, only the

indoor remote temperature reading will be used for

control .

22)

Select Change Filter Run Time – The thermostat will

display

"Change Filter" after a set time of blower opera-

tion. This is a reminder to change or clean your air filter.

This time can be set from 25 to 1975 hours in 25 hour

increments . A selection of OFF will cancel this feature .

When

"Change Filter" is displayed, you can clear it by

pressing Clean Display . In a typical application, 200 hours

of run time is approximately 30 days .

INSTALLER/CONFIGURATION MENU