Location requirements, Air gap requirements – Whirlpool WHES30 User Manual
Page 9
9
Location Requirements
Consider all of the following when selecting an installation location for the water softener.
•
Do not locate the water softener where freezing temperatures occur. Do not attempt to
treat water over 120_F. Freezing, or hot water damage voids the warranty.
•
To condition all water in the home, install the water softener close to the water supply
inlet, and before all other plumbing connections, except outside water pipes. Outside
faucets should remain on hard water to avoid wasting conditioned water and salt.
•
A nearby drain is needed to carry away regeneration discharge (drain) water. Use a floor
drain, laundry tub, sump, standpipe, or other options (check your local codes). See “Air
Gap Requirements” and “Valve Drain Requirements” sections.
•
The water softener works on 24 volt--60 hz electrical power only, supplied by a direct
plug--in transformer (included). Provide an electrical outlet in accordance with NEC and
local codes.
•
Always install the water softener between the water heater and water inlet. Any other
installed water conditioning equipment should be installed between the water softener
and the water inlet (see Figure 1 below).
water softener
cold to
water heater
optional
sediment
filter
pressure tank
well pump
city water supply
well water supply
OR
Figure 1
Air Gap Requirements
A drain is needed for regeneration discharge water. A floor drain, close to the water softener, is
preferred. A laundry tub, standpipe, etc., are other drain options. Secure valve drain hose in place.
standpipe
1---1/2”
airgap
drain
hose
1---1/2”
airgap
drain
hose
laundry tub
floor drain
drain
hose
1---1/2”
airgap
Figure 2