beautypg.com

Add water and salt to the salt storage tank, Sanitize the softener/sanitize after service, Plug in water softener – Whirlpool WHES30 User Manual

Page 16

background image

16

Add Water and Salt to the Salt Storage Tank

1.

Using a container, add about three gallons of clean water into the salt storage tank.

2.

Add salt to the storage tank. Use nugget, pellet or coarse solar salts with less than 1% impurities.

NOTE:

See “Routine Maintenance Section” for additional information on salt.

Persons who are on sodium restricted diets should consider the added sodium as part of their overall sodium intake.
For example, if your water supply is 15 grains hard, and you drank 3 quarts of softened water you would consume
335 milligrams of sodium. That is equivalent to eating 2--1/2 slices of white bread.
NOTE:

The salt monitor system is calibrated to the density of nugget or pellet water softener salt. The monitor
will not work as accurately with other types of salt including rock and solar.

If you choose Potassium Chloride (KCl) as a regenerant, following these suggestions will help give you years of
maintenance free service.

1. Place only one bag of

KCl in your softener at a time (the salt storage tank should contain no more than 60

pounds of KCl at any one time).

2.

A softener using KCl should not be placed in areas with temperature fluctuations and high humidity (KCl will

harden in these environments and may make the softener inoperable).

3.

Check the brine tank and brine well (black tube in salt storage tank) monthly. If hardening is present, pour small

amounts of warm water on hardened areas until they loosen.

4.

If your softener does not have a KCl salt setting you must increase your hardness setting by 25% to ensure

continuous soft water as in example below.

Raw Water Hardness

Softener Setting

Raw Water Hardness

Softener Setting

(Grains per Gallon)

When Using KCl

(Grains per Gallon)

When Using KCl

5 gpg

+ 25 % =

7 gpg

25 gpg

+ 25% =

32 gpg

10 gpg

13 gpg

30 gpg

38 gpg

15 gpg

19 gpg

35 gpg

44 gpg

20 gpg

25 gpg

40 gpg

50 gpg

Sanitize the Softener/Sanitize After Service

1.

Open salt hole cover and remove the brinewell cover and pour about 1--1/2 oz. (2 to 3 tablespoons) of household
bleach into the softener brinewell. Replace the brinewell cover.

2.

Make sure the bypass valve(s) is in the service (open) position.

3.

Sanitize procedure will be completed when first cycle is run and sanitizing solution is flushed from the water
softener.

Plug in Water Softener

During installation, the water softener wiring may be moved or jostled from place. Check to be sure all leadwire
connectors are secure on the back of the electronic board and be sure all wiring is away from the valve gear and motor
area, which rotates during regenerations.

1.

Plug the water softener into an electrical outlet that is not controlled by a switch.

NOTE:

The water heater is filled with hard water and, as hot water is used, it refills with conditioned water. In a few days, the
hot water will be fully conditioned. To have fully conditioned hot water immediately, wait until the initial recharge
is over. Then, drain the water heater (following instructions for water heater) until water runs cold.