beautypg.com

Manual advance regeneration check --- model whes30 – Whirlpool WHES30 User Manual

Page 33

background image

33

Press

Down to display the number of regenerations initiated by this electronic

control since the LE code number was entered.

6. Press and hold the

PROGRAM button until LE31 shows in the display.

This code identifies the softener model. If the wrong number shows, the softener will operate on

incorrect programming.

7. Return the present time display — Press the

PROGRAM button.

8. To change LE number — Press the

+

Up or

Down button until the correct code shows.

Then, press the

PROGRAM button to return to the present time display.

Manual Advance Regeneration Check --- Model WHES30

This check verifies proper operation of the valve motor, brine tank fill, brine draw, regeneration flow

rates, and other controller functions. Always make the initial checks, and the manual initiated

diagnostics.

NOTE:

The electronic control display must show a steady time (not flashing). If an error code
shows, first press the

PROGRAM button to enter the diagnostic display.

1. Press the

RECHARGE button and hold in for 3 seconds. RECHARGE begins to flash as the

softener enters the fill cycle of regeneration. Remove the brinewell cover and, using a flashlight,

observe fill water entering the tank.

If water does not enter the tank, look for an obstructed nozzle, venturi, fill flow plug, brine tubing, or

brine valve riser pipe.
2. After observing fill, press the

RECHARGE button to move the softener into brining. A slow

flow of water to the drain will begin. Verify brine draw from the brine tank by shining a flashlight

into the brinewell and observing a noticeable drop in the liquid level. This may take 15 to 20

minutes to notice.

NOTE:

Be sure water is in contact with the salt, and not separated by a salt bridge... see “Breaking

A Salt Bridge” section.

If the water softener does not draw brine, check for (most likely to least likely)

Dirty or plugged nozzle and venturi, see “Cleaning the Nozzle and Venturi” section

Nozzle and venturi not seated on the gasket, or gasket deformed

Restriction in valve drain, causing a back--pressure (bends, kinks, elevated too high, etc.),

see “Install Valve Drain Hose” section

Obstruction in brine valve or brine tubing

Inner valve failure (obstructed outlet disc, wave washer deformed, etc.)

NOTE:

If water system pressure is low, an elevated drain hose may cause back pressure, stopping

brine draw.

3. Again, press the

RECHARGE button to move the softener into backwash. Look for a fast flow

of water from the drain hose.

An obstructed flow indicates a plugged top distributor, backwash flow plug, or drain hose.