beautypg.com

Tube layout drawing - typical, Alumipex radiant tubing – Weil-McLain AlumniPEX Radiant Heater User Manual

Page 6

background image

AlumiPex Radiant Tubing

Part Number 650-000-221/0298

6

Normal

Close

Inches

Inches

Feet

Feet

Feet

Feet

LR1

Low pile carpet w/ thermal pad

8.5

178

43

10

231

LR2

Low pile carpet w/ thermal pad

8.5

6.5

192

22

10

224

DK

Laminated hardwood

12.5

6.5

227

28

10

265

UT

Ceramic tile

6.5

45

4

10

59

BT

Ceramic tile

6.5

79

12

10

101

BR1

Laminated hardwood

8.5

6.5

141

22

10

173

BR2

Laminated hardwood

8.5

6.5

163

22

10

195

BR3

Laminated hardwood

8.5

6.5

156

19

10

185

Coil

Number

Coil Length

Tube Size

Total

Length

1

1000 feet

1/2"

974

2

300 feet

1/2"

286

3

300 feet

1/2"

173

Use for Circuits Listed

Tubing

Circuit

Finished
Flooring

Total

Tube

Length

Tube Spacing

(Center to Center)

Circuit

Length

Leader

Length

Length

Allowance

LR1, LR2, DK, UT & BR2

BT & BR3

BR1

washer / dryer

Slab Control Joint

This drawing is conceptual only. Consult Weil-McLain Radiant Guides or Software for actual project layout.

DINING

BEDROOM

BEDROOM

BEDROOM

KITCHEN

U

T

I

L

I

T

Y

B

A

T

H

MANIFOLD

LIVING ROOM

DK

LR1

LR2

BR2

BR3

BT

UT

BR1

TUBE LAYOUT DRAWING -

Typical

Figure 6 - Typical tube layout drawing