Tube layout drawing - typical, Alumipex radiant tubing – Weil-McLain AlumniPEX Radiant Heater User Manual
Page 6
AlumiPex Radiant Tubing
Part Number 650-000-221/0298
6
Normal
Close
Inches
Inches
Feet
Feet
Feet
Feet
LR1
Low pile carpet w/ thermal pad
8.5
178
43
10
231
LR2
Low pile carpet w/ thermal pad
8.5
6.5
192
22
10
224
DK
Laminated hardwood
12.5
6.5
227
28
10
265
UT
Ceramic tile
6.5
45
4
10
59
BT
Ceramic tile
6.5
79
12
10
101
BR1
Laminated hardwood
8.5
6.5
141
22
10
173
BR2
Laminated hardwood
8.5
6.5
163
22
10
195
BR3
Laminated hardwood
8.5
6.5
156
19
10
185
Coil
Number
Coil Length
Tube Size
Total
Length
1
1000 feet
1/2"
974
2
300 feet
1/2"
286
3
300 feet
1/2"
173
Use for Circuits Listed
Tubing
Circuit
Finished
Flooring
Total
Tube
Length
Tube Spacing
(Center to Center)
Circuit
Length
Leader
Length
Length
Allowance
LR1, LR2, DK, UT & BR2
BT & BR3
BR1
washer / dryer
Slab Control Joint
This drawing is conceptual only. Consult Weil-McLain Radiant Guides or Software for actual project layout.
DINING
BEDROOM
BEDROOM
BEDROOM
KITCHEN
U
T
I
L
I
T
Y
B
A
T
H
MANIFOLD
LIVING ROOM
DK
LR1
LR2
BR2
BR3
BT
UT
BR1
TUBE LAYOUT DRAWING -
Typical
Figure 6 - Typical tube layout drawing