beautypg.com

Programming troubleshooting – White Rodgers 1F85-0477 User Manual

Page 10

background image

10

Worksheet for Re-Programming 7 Day and 5+1+1 Day Program

Cooling

Program

Wake Up

(Period 1)

Leave For Work

(Period 2)

Return Home

(Period 3)

Go To Bed
(Period 4)

MON

6:00 AM

75°F

8:00 AM

83°F

5:00 PM

75°F

10:00 PM

78°F

TUE

WED

THU

FRI

SAT

6:00 AM

75°F

8:00 AM

83°F

5:00 PM

75°F

10:00 PM

78°F

SUN

6:00 AM

75°F

8:00 AM

83°F

5:00 PM

75°F

10:00 PM

78°F

Heating

Program

Wake Up

(Period 1)

Leave For Work

(Period 2)

Return Home

(Period 3)

Go To Bed
(Period 4)

MON

6:00 AM

70°F

8:00 AM

62°F

5:00 PM

70°F

10:00 PM

62°F

TUE

WED

THU

FRI

SAT

6:00 AM

70°F

8:00 AM

62°F

5:00 PM

70°F

10:00 PM

62°F

SUN

6:00 AM

70°F

8:00 AM

62°F

5:00 PM

70°F

10:00 PM

62°F

PROGRAMMING

TROUBLESHOOTING

Comfort Alert Codes
The Comfort Alert diagnostics product monitors the air
conditioning outdoor systems with single phase Copeland
Scroll compressors. Abnormal system and electrical
conditions are indicated by flashing ALERT codes on the
yellow LED on the Comfort Alert module. The flash codes are
transmitted to the thermostat by the Comfort Alert Thermostat
interface module. The Comfort Alert compatible thermostat
displays

“Call For Service” that flashes at the same rate as

the yellow LED on the Comfort Alert module.

Comfort Alert Yellow Alert Codes

1 Flash

Long run time

2 Flashs

System pressure trip

3 Flashs

Short cycling

4 Flashs

Locked rotor

5 Flashs

Open circuit

6 Flashs

Open start circuit

7 Flashs

Open run circuit

8 Flashs

Welded Contactor

9 Flashs

Low voltage