beautypg.com

Windsor ADMIRAL PLUS ADP User Manual

Page 7

background image

WARNING:

Removethe machine power

cord from the electrical source before
making any adjustments or repairs.
ONLY QUALIFIED MAINTENANCE PER-
SONNEL ARE TO PERFORM REPAIRS.

HANDLE LOCKADJUSTMENT

The black knob on the opposite end of the

rod from the adjusting lever controls the

tightness of the adjusting knob.

VAC SHOE

Remove the screws holding the parallel

arms to take off the vac shoe for repairs or
replacement.

When reinstalling the vac shoe be sure that
the wave washers are floating and not

pinched.

BRUSH ASSEMBLY AND BEARINGS

1. Remove belt guard and roll belt off motor
pulley.

2. Tilt machine back on handle and remove

brush pulley guard.

3. Remove shaft retaining screws and
washers from each end of the brush shaft.

4. Replace brush or bearings as required.

TRANSPORT WHEELS

Remove screw and hub cap to service

wheel.

Before putting wheel back on clean axle and
apply a light coat of silicon lubricant.

SUPPORT ROLLER

1. Tilt machine back on handle.

2. Loosen lock nuts on each end of roller

axle and remove assembly.

3. Replace and repair as necessary.

4. Clean axle and apply a light coat of

silicon lubricant before reassembling.

SWITCH CONTROL PANEL

The switches and circuit breakers are ac-
cessed through the panel located on the bot-
tom of the control panel.

CAUTION:

After making repairs use the wiring diagram

located on the access panel or in this manual

to be sure all wire leads are properly con-

nected.

ACCESSING THE CHASSIS

1. Drain both tanks completely.

2. Remove dome and recovery tank.

3. Tilt machine back on handle and remove

(4) nuts holding solution tank to chassis.

4. Return machine to upright position.

5. Raise tank and remove hose from pump

inlet and set solution tank aside.

PUMP

1. Access chassis as described above.

2. Disconnect wire leads.

3. Remove (4) screws attaching pump to

chassis.

4. Disconnect hoses and remove pump.

Refer to the pump assembly drawing for in-

ternal parts and repairs.

CAUTION: Do not over-tighten the
barbs on the pump head. Over-tightening

the hosebarbs can cause the pump head to

crack and begin leaking.

WARNING:

The internal solution hoses

are encased in an outer hose to protect
the electrical component parts in the un-

likely event a solution hose should rup-

ture. Replace hoses exactly as originally

supplied.

This manual is related to the following products: