Wiring diagrams, Figure 3 – heat pump systems heat pump connections, Single stage and multi-stage connections – White Rodgers 1F95-1291 User Manual

Page 3: Single stage (ss 1), Multi-stage (ms 2), Heat pump type 1 (hp 1), Heat pump type 2 (hp 2), Gas, oil or electric

background image

3

WIRING DIAGRAMS

Figure 2 – Single Stage or Multi-Stage System

(No Heat Pump) with Single Transformer

Single Stage 1

(SS1)

Multi Stage 2

(MS2)

System

RC

RH

C

Y

Y2

W/E

W2

G

O/B

6

L

CLASS II

TRANSFORMER

HOT

24VAC

NEUTRAL

120VAC

Call for heat

Heat mode-1st

stage

Heat mode-2nd

stage

No output

24 volt

power for

cooling

24 volt

power for

heating

Cool mode-2nd

stage

24 volt

common

(optional

for system

operation,

required

for remote

sensor)

Call for cool

No Output

Cool mode-1st

stage

Blower/Circulator fan

energized on a call

for cool or Fan On

(also energized in

heating if configured

for Electric Heat)

Installer

Configuration

Menu selects

“O” or “B” for

changeover

function. Set

to “O” terminal

energized in Cool

& Off mode. Set

to “B” terminal

energized in

Heat & mergency

mode

Power closed

connection for

SPDT 3-wire

zone valve

Fault or System

Malfunction

Indicator for

Heat Pumps

with “L” terminal

connection.

Original production

1F95-1291’s

do not have this

connection

Figure 3 – Heat Pump Systems

Heat Pump Connections

If you do not have a heat pump system, refer to figures 3 & 4.
Refer to equipment manufacturers’ instructions for specific system
wiring information.
You can configure the thermostat for use with the following heat pump
systems.

Single Stage and Multi-Stage Connections

Refer to equipment manufacturers’ instructions for specific system
wiring information.
This thermostat is designed to operate a single-transformer or two-
transformer system.
You can configure the thermostat for use with the following fossil fuel
systems:

Heat

Pump 1

(HP1)

Heat

Pump 2

(HP2)

System

RC

RH

C

Y

Y2

*W/E

*W2

G

O

6

L

CLASS II

TRANSFORMER

HOT

24VAC

NEUTRAL

120VAC

Heat mode-2nd

stage, Emergency

Mode-1st stage

*Note: Dual Fuel

option de-

energizes Heat

mode stage 1

(compressor)

when auxiliary

heat is energized

Heat mode-3rd

stage, Emergency

Mode-1st stage

*Note: Dual Fuel

option de-

energizes Heat

mode stages 1

and 2 (both

compressors)

when auxiliary

heat is energized

Heat mode-4th

stage, Emergency

Mode-2nd stage

*Note: Dual Fuel

option de-

energizes Heat

mode stages 1

and 2 (both

compressors)

when auxiliary

heat is energized

Heat mode-3rd

stage, Emergency

Mode-2nd stage

*Note: Dual Fuel

option de-

energizes Heat

mode stage 1

(compressor)

when auxiliary

heat is energized

24 volt

power for

cooling

24 volt

power for

heating

Heat mode-2nd

stage,

Cool mode-2nd

stage,

(Compressor)

No Output

24 volt

common

(optional

for system

operation,

required

for remote

sensor)

Heat mode-1st

stage,

Cool mode-1st

stage,

(Compressor)

Blower/Circulator fan

energized on a call

for cool or Fan On

(also energized in

heating if configured

for Electric Heat)

Installer

Configuration

Menu selects

“O” or “B” for

changeover

function. Set

to “O” terminal

energized in Cool

& Off mode. Set

to “B” terminal

energized in

Heat & mergency

mode

Power closed

connection for

SPDT 3-wire

zone valve

Fault or System

Malfunction

Indicator for

Heat Pumps

with “L” terminal

connection.

Original production

1F95-1291’s

do not have this

connection

COOLING

CLASS II

TRANSFORMER

HOT

24VAC

NEUTRAL

120VAC

HEATING

120VAC

*Dual fuel option, if selected turns off compressor(s) when Auxiliary stages energize.

SINGLE STAGE (SS 1)

gas, oil or electric.

MULTI-STAGE (MS 2)

gas, oil or electric.

After wiring, see INSTALLER CONFIGURATION section for proper
thermostat configuration.

HEAT PUMP TYPE 1 (HP 1)

.

Single stage compressor system;

gas or electric backup.

HEAT PUMP TYPE 2 (HP 2).

Multi-stage compressor or two

compressor system with gas or electric backup.

After wiring, see INSTALLER CONFIGURATION section for proper
thermostat configuration.