beautypg.com

Operating your thermostat – White Rodgers 1F95-1291 User Manual

Page 11

background image

11

Choose the System Setting

(Cool, Off, Heat, Em, Auto)

Press the SYSTEM key to select:
Cool: Thermostat controls only the cooling system.
Off: Heating and Cooling systems are off.
Heat: Thermostat controls only the heating system.
Em: Setting is available only when the thermostat is config-
ured in HP1 or HP2 mode.
Auto: Auto Changeover is used in areas where both heating
and cooling may be required on the same day.

AUTO allows

the thermostat to automatically select heating or cooling
depending on the indoor temperature and the selected heat
and cool temperatures. When using

AUTO, be sure to set the

Cooling temperatures more than 1° Fahrenheit higher than
the heating temperature.

Manual Operation for

Non-Programmable Mode

Press the SYSTEM key to select

"Heat" or "Cool" and use

the keys to adjust the temperature to your desired setting.
After selecting your desired settings you can also press the
SYSTEM key to select

AUTO to allow the thermostat to auto-

matically change between

"Heat" and "Cool".

Manual Operation (Bypassing the Program)

Programmable Mode

Manual operation will bypass the program and allow you to
adjust the temperature as you desire. The temperature you
set in

Hold will be maintained indefinitely. Press or to

adjust the temperature. The HOLD key will appear. Press the
HOLD key. "

Hold At" will appear next to the setpoint tem-

perature and the thermostat will maintain the new setpoint
temperature until

Run Schedule is pressed to resume pro-

gram operation.

Program Override (Temporary Override)

Press

or

keys to adjust the temperature. This will over-

ride the temperature setting for a (default) four hour override
period. The override period can be shortened by pressing
or lengthened by pressing . Program Override period can
range from 15 minutes to 7 days.
Example: If you turn up the heat during the morning program,
it will be automatically lowered later, when the temporary hold
period ends. To cancel the temporary setting at any time and
return to the program, press

Run Schedule.

If the SYSTEM key is pressed to select

AUTO the

thermostat will change to

"Heat" or "Cool", whichever

ran last. If it switches to

"Heat", but you want "Cool", or it

changes to

"Cool", but you want "Heat", press both keys

simultaneously to change to the other mode.

OPERATING YOUR THERMOSTAT

Cooling/Dehumidifier

1. Press SYSTEM to select

"Cool".

2. Press

to adjust the thermostat setting below room tem-

perature. The blower should come on immediately on high
speed, followed by cold air circulation. The display should
show "

System On". If the setpoint temperature display is

flashing, the compressor lockout feature is operating (see
Configuration menu, item 5).

3. Adjust temperature setting to 3° below room temperature.

The second stage cooling should begin to operate and the
display should show

"System On +2".

4. Press

to adjust the temperature setting above room

temperature. The cooling system should stop operating.

To check the dehumidifier when

System On appears and

the cooling system is running press *

HUMIDITY button once.

Press

to adjust the humidity 2% or more below the room

humidity level.

DeHum On will appear indicating it is calling

for the dehumidification.
If the room humidity is lower than the adjustment range, press

to 40% and hold it for four seconds. This will force the

DeHum On for one complete cooling cycle to test the dehu-
midification equipment.
After adjusting the humidity setting the display will return to
temperature in approximately 10 seconds. To switch the dis-
play back to temperature immediately after adjusting humidity
setting press

HUMIDITY again.

*Note: If Auto Schedule is displayed instead of Humidity, Auto
Schedule must be turned off in the Configuration Menu.

Choose the Fan Setting (Auto or On or Prog)

There are three fan features on the 1F95-1291:
1.

Fan Auto/On – Traditional Fan Settings

Press Fan to select Auto or On. The most commonly

used setting is

Auto. Fan Auto runs the fan only when

the heating or cooling system is operating. Selecting

Fan

On runs the fan continuously for increased air circulation
or to allow additional air cleaning if the system is equipped
with an Electronic Air Cleaner.

2.

FAN Prog – Comfort Circulating Fan Feature

Pressing FAN until FAN Prog appears activates the Com-

fort Circulating Fan Option. This causes the thermostat to
cycle the fan on for 10 minutes and off for 20 minutes if the
thermostat has not called for heat or cool during the past
60 minutes. This assures moderate air circulation even
when the heating and cooling equipment is not cycling.

3.

FAN On Prog. – Programmable Fan

FAN On Prog indicates that a time period has FAN Prog
selected in the Set Schedule mode (see Programmable
Fan Option). The fan will run continuously through the pe-
riod until the next period begins. To override

FAN On Prog,

press the

FAN key to select Auto for the fan to run only

when the heating or cooling system is operating.

Tip: Running the fan more frequently will increase your

energy consumption. Most systems use a 1/2 or 1/3 HP
electric motor to power the fan.