beautypg.com

Windsor Saber Blade 12 User Manual

Page 11

background image

English

11

Error

Remedy

Appliance cannot
be started

Check if the mains plug is connected.

Insufficient water
quantity

Check clean water level, refill tank if necessary.

Clean the water distributor (see chapter "Cleaning the water
distributor").

Pull off the valve on thesolution tank (Fig. 4, see inside front
cover) and rinse in lukewarm water.

Fresh water reser-
voir drips when re-
filled

Pull off the valve on the solution tank (Fig. 4, see inside front
cover) and rinse in lukewarm water.

Insufficient vacu-
um performance

Empty the solution tank.

Lock the recovery tank in place on the appliance.

Clean the seals between recovery tank and cover and
check for tightness, replace if required.

Check that all squeegee are locked into place in the clean-
ing head.

Squeegee worn, replace if required.

Check that both suction tube parts are correctly attached to
the suction tube connection.

Check the suction tube and the suction channel in the
cleaning head for obstruction and remove if necessary (see
"Cleaning suction tube").

Insufficient clean-
ing result

Check the brush for wear, replace if required.

Brush does not
turn

Check if foreign matters are blocking the brush; remove for-
eign matter if required.