Caution – White Rodgers 1F95W-71 User Manual

Page 5

background image

5

CAUTION

!

NOTE

NOTE

C

R

O

B

CHANGEOVER

ENERGIZED

IN HEAT

CHANGEOVER

ENERGIZED

IN COOL

G

FAN

RELAY

HEAT

RELAY

STAGE 1

HEAT

RELAY

STAGE 2

HEAT

RELAY

STAGE 3

THERMOSTAT

CONTROL

CIRCUIT

24 VAC

120 VAC

HOT

NEUTRAL

THERMOSTAT

SYSTEM

COMPRESSOR

CONTACTOR

STAGE 1

Y1

COMPRESSOR

CONTACTOR

STAGE 2

Y2

W1

W2

W3

Figure 5. Typical wiring diagram for two-transformer systems with NO safety circuits

TWO COMMONS MUST

BE JUMPERED TOGETHER!

HOT

NEUTRAL

120 VAC

24 VAC

CUT AND

TAPE OFF!

DEPENDING ON SYSTEM

REQUIREMENTS, REPLACE WITH

A 75VA TRANSFORMER, IF NEEDED

Relay contacts shown are thermostatically operated. The
accessory relay scheme is required when safety circuits
exist in both systems.

Polarity must be observed. If the HOT side of the
second transformer is jumpered to the COMMON
side of the first transformer a short will be made.
Damage to equipment will occur when power is
restored.

IF SAFETY CIRCUITS ARE IN ONLY ONE OF THE
SYSTEMS, REMOVE THE TRANSFORMER OF THE
SYSTEM WITH NO SAFETY CIRCUITS.

C

R

O

B

CHANGEOVER

ENERGIZED

IN HEAT

CHANGEOVER

ENERGIZED

IN COOL

G

FAN

RELAY

HEAT

RELAY

STAGE 1

HEAT

RELAY

STAGE 2

HEAT

RELAY

STAGE 3

THERMOSTAT

CONTROL

CIRCUIT

24 VAC

120 VAC

HOT

NEUTRAL

THERMOSTAT

SYSTEM

COMPRESSOR

CONTACTOR

STAGE 1

Y1

COMPRESSOR

CONTACTOR

STAGE 2

Y2

W1

W2

W3

Figure 6. Typical wiring diagram for two-transformer systems with safety circuits in BOTH systems

TWO COMMONS MUST

BE JUMPERED TOGETHER!

HOT

NEUTRAL

120 VAC

LIMIT OR

SAFETY

SWITCHES

LIMIT OR

SAFETY

SWITCHES

LIMIT OR

SAFETY

SWITCHES

24 VAC

LIMIT OR

SAFETY

SWITCHES

COMMON

COMMON

HEATING

TRANSFORMER

COOLING

TRANSFORMER

24 VAC

ACCESSORY

RELAY N.O.

CONTACT