Pro hood liner installation, In-line and remote blowers – Wolf Appliance Company L342212 User Manual
Page 13
Pro Hood Liner Installation
13
wolfappliance.com/specs
Before making electrical connections, make sure the
electrical power is turned off at the service panel.
4)
Locate the cord assembly provided with the blower.
The cord assembly has two leads, black (L1) and white
(neutral). Connect these leads to the leads from the
blower, black to black and white to white. Connect all
green and bare wires together to the ground screw in
the electrical box.
5) Plug the cord assembly into the receptacle located
near the center of the hood liner. Refer to the illustra-
tion below. Use the clips on the interior of the hood to
secure excess power cord.
6) Place all wiring connections inside the electrical box
and reinstall the cover. Make sure all wires are secure
and that no wires are pinched between the cover and
electrical box.
IMPORTANT NOTE:
Before turning the power on to the
ventilation hood liner, make sure the blower is off.
KNOCK-OUTS
Location of knock-outs.
Location of receptacle(s).
BLOWER
RECEPTACLE(S)
In-Line and Remote Blowers
BLOWER WIRING
IMPORTANT NOTE:
Refer to specific installation instruc-
tions provided with each blower assembly for additional
mounting and wiring instructions.
1) Remove the two knock-outs in the top plate of the
hood liner. Refer to the illustration below.
2) Follow wiring instructions at the blower (specific wiring
instructions are provided with each blower). Run
Romex
®
wire from the in-line or remote blower to the
hood liner.
3) Insert 6"
(152)
of Romex
®
wire through the holes on the
back plate and into the hood liner. Secure the wire to
the electrical box with an appropriate connector.
Do not run wiring through the ductwork.