beautypg.com

WhisperKool 17-1103 User Manual

Page 29

background image

-27-

Conclusions

After completing the temperature differential test, determine if the unit is not cooling at all or if
it is not cooling enough.

If the unit is not cooling at all, contact Vinothèque Customer Service at 800.343.9463. Be sure
to have the measurements and results from your Temperature Differential test available.

If the unit is cooling but not cooling fully (with a evaporator differential of 10°F-15°F and a
condenser differential of approximately 30°F), it indicates that there is too much heat on the back
side of the unit. In this case, you should:

Check to make sure that there is at least 3’ of unobstructed space in front of the fans/vents
to allow adequate ventilation. Improper ventilation causes the majority of problems with
cooling units.

On the condenser side, if the inlet air temperature is >90°F and/or the outlet air
temperature is >120°F, there is too much heat on the back side of the unit which is
preventing it from cooling fully. To remedy this, heat needs to be dissipated away from the
unit through an exhaust fan or other means of ventilation on the exhaust side. You can
contact Vinothèque Customer Service to request a ducting flange adapter at no charge to

assist in directing heat away from the unit (for warranty units only).

You might consider installing a Vinothèque approved ventilation ducting system for your unit
which can be obtained through Vinothèque Customer Service.

·

Contact Vinothèque Customer Service at 800.343.9463. Be sure to have the measurements
and results from your Temperature Differential test available.

This manual is related to the following products: