beautypg.com

Troubleshooting guide – WhisperKool 17-1103 User Manual

Page 20

background image

-18-

Problem

Likely Cause

Remedy

The unit does not
cool the room

Inadequate door seal

See “Door Seal” section on pg. 20

Improperly mounted unit

See “Unit Mounting” section on pg. 20

Unit has inadequate ventilation

See “Airflow” and “Ventilation” sections on pg. 19

Foam strips are not attached

See page 11 (in the “Installation” section)

Water leaking

Condensate Evaporator is not

See

Water Leaking, Rear in the

from the rear

properly set for local climate

“Condensation” section on pg. 21

Drain line is not attached

See “Drain line” section on pg. 21

Unit is icing up

Thermostat is faulty

See “Thermostat” section on pg. 20

Unit is low on refrigerant

See “Icing Up” section on pg. 21

Unit isn’t running

Problem with local electrical

See “Power Requirements” section on pg. 21

or makes intermittent circuit
clicking noises

Try this first!

Clean off any accumulated dust, lint, or other debris from the front and rear
intake grills. This will restrict the airflow and may affect the unit’s ability to
function properly. Periodically cleaning the unit’s vents will help assure
maximum cooling efficiency.

Airflow

Proper airflow is critical to the performance of the WhisperKOOL unit. Any
obstruction to the intake and exhaust ports on either side of the unit will
compromise the unit’s ability to cool. Make sure the WhisperKOOL unit fan vents
are clear. Check the front and rear intake vents for any possible obstruction.
There should be a minimum clearance of three feet directly in front of the intake
and exhaust vents.

TROUBLESHOOTING GUIDE

Before contacting Customer Service regarding a performance issue with your cooling unit
(does not cool, leaks, ices up…), please review the following troubleshooting information and
complete the Troubleshooting Checklist found on page 23. It is designed to help you identify
the issue yourself and provide appropriate advice to remedy the issue or problem.

If you are unable to identify or solve the issue after completing and following these steps, fax
a completed Troubleshooting Checklist to Vinotheque Customer Service at 209.466.4606. The
checklist will provide Customer Service with background information on your cooling unit
installation and wine cellar to better assist you in resolving the issue. Be sure to include
accurate contact information